6
KAC-PS4D/X4R
Pin No.
Pin Name
I/O
Application
Processing / Operation / Description
37
5V_SW
O
SW5V ON/OFF
SW5V ON/OFF
Power supply ON: H, Initial condition L
38
VD DOWN
I
Detection of voltage at momentar y
power down
H: Processing to detect voltage at momentary power down
(Enter the stop mode when the P-CON is down.)
39
FAN_CTRL
O
FAN control
H: FAN_ON
40
PON_ILLUM
O
LOGO LED+B SW
H: ON, L: OFF, Initial condition L
41
PON_FL
O
FL power supply (Grid and Filament)
control
H: ON, L: OFF
42
/VFD_INH (/BLK)
O
Inhibit FL driver display
H: Display, L: No display
43
VFD_CE
O
44
VFD_DATA_M (FVD.DI)
O
45
VFD_DATA_S (FVD.DO)
I
46
VFD_CLK
O
47
AVREF
-
DA REF voltage
48
AVSS
-
49
AD_V
I
Detects BU voltage (For display)
Displays the voltage and condition.
50
AD_I
I
Detects primary current (For display)
Converts into the current and displays current value.
51
TEMP6
I
Temperature detection 6 (at power
supply side) (For display and protection)
Displays the temperature and overheat protection.
52
TEMP5
I
Temperature detection 5 (at power
supply side) (For display and protection)
Displays the temperature and overheat protection.
53
TEMP4
I
Temperature detection 4 (at power
supply side) (For display and protection)
Displays the temperature and overheat protection.
54
TEMP3
I
Temperature detection 3(at power
supply side) (For display and protection)
Displays the temperature and overheat protection.
55
TEMP2
I
Temperature detection 2 (at power
supply side) (For display and protection)
Displays the temperature and overheat protection.
56
TEMP1
I
Temperature detection 1 (at power
supply side) (For display and protection)
Displays the temperature and overheat protection.
57
NC
O
Not used
Output L fi xed
58
E2P_SCL
I/O To memorize D2 setting
59
E2P_SDA
I/O To memorize D2 setting
60,61
NC
O
Not used
Output L fi xed
62
B_DET I
B voltage over voltage detection
(Not Used)
Plan: Enters the protection operation when the voltage is
higher than a certain value.
(Not Used)
• Software does not have a detection function.
• Make sure to pull down/up when it is required to remove
the external circuit!
63
/DC_DET
I
Output DC OFFSET voltage detection
L: Enters into the voltage error protection operations.
64
USB_DET (Not Used)
I
USB detection
H: When USB is detected, do not make D2 setup from the
µ-com.
• No processing is included.