9
KAC-8102D/8152D
KAC-9102D/9152D
K
L
M
N
O
1
2
3
4
5
6
7
X08-4180-1x (1/1), X09-5820-1x B/2 (1/1)
15.0V
0V
-15.0V
0V
15.0V
15.0V
0V
0V
0V
-15.0V
0V
15.0V
0V
0V
0V
0V
-15.0V
-15.0V
0V
0V
15.0V
0V
0V
0V
0V
0V
-15.0V
0V
0V
15.0V
(X09- ) (B/2)
B
BASS BOOST
∗
(X08-) (B/2)
A
REMOTE
KAC-8102D/8152D/
9102D/9152D (2/2)
(X08-4180-xx) (A/2)
(2/2)
IC12
∗
A
(1/2)
IC14
(2/2)
IC14
(1/2)
IC15
(2/2)
IC15
OFF/15Hz/25Hz
OFF/ON
S1
(1/2)
IC11
S2
(2/2)
IC11
I.N.V
I.F.S
CN1
CN2
WH2
: B30-1601-05
D81
D81
J4
1/2
X09-A/2
J1
B.
B
B.
B
CN1
1/2
X09-A/2
FREQ.
LEVEL
SENS
IC13
(1/2)
IC12
(1/2)
L.P.F
(2/2)
IC13
(X08-4180-xx)
B LINE
B LINE
GND LINE
SIGNAL LINE
: RC4580IDR
IC11-15
BASS BOOST
2.2K
R204
R208
18K
10K
R201
5
6
7
8
3K
R203
5
C204
+15V
2
8
3
1
6
7
8
0.1
6
5
VR3
7
0.01
C203
4
10K
R202
100P
C201
TP28
TP27
10K
R205
39K
R206
TP32
10K
R207
18K
R210
3
4
TP50
C205
0.1
R209
39K
2
TP35
8
1
10K(1B)
R212 22K
TP51
TP52
47P
C208
22K
R211
4
C206
0.01
C202
0.01
0.01
C108
0.01
C109
C207
0.01
C124
2.2u50
2
1
3
5
4
7
6
8
TP17
2
3
1
8
TP16
R106
3.9K
TP18
2
1
5
3
4
10
9
6
7
8
5
6
7
10u50
C102
4
10u50
+
C101
10K
R101
10K
R103
TP14
TP12
TP11
TP15
1u50
+
C105
1u50
+
C106
R105 47K
47K
R104
6.8K
R108
R107
30K
R109
24K
TP20
0.01
C103
TP13
TP19
8
7
6
5
4
3
2
1
SIG 1
ISO GND 1
SIG 2
ISO GND 2
-15V
+15V
D GND
LED
10u50
+
C121
∗
W151
TP2
TP1
TP3
TP4
TP5
TP8
TP7
1
2
3
0.01
C81
3
2
1
TP82
TP81
2
TP65
3
4
R624
8.2K
TP62
TP61
1
TP60
10K(C)
VR61
2K
10K(C)
R623
VR62
TP63
TP64
3
C119
R124
12K
TP41
R125
5.1K
2
3
R111
47K
VR1
10K(C)
430
R127
R113
C107
10u16
R110
1K
TP23
TP24
+
R123
2
5.6K
C115
TP26
0.15
0.068
C116
3
TP40
C118
0.068
15K
1
R119
15K
R112
TP25
1
R120
15K
3.3K
R121
50K
TP39
C117
0.022
TP36
5
VR2
9
6
8
7
4
C123
0.15
4
TP44
0.01
8
6
5
7
C120
0.033
2.2K
21
KAC-8102D(K)
0-11 YES
MODEL NAME
0-10
NO
UNIT
No.
A
NO
YES
W151
KAC-8152D(E)
KAC-9152D(E)
KAC-8152D(M)
KAC-9152D(M)
KAC-8152D(K)
KAC-9152D(K)
KAC-9102D(K)
NO
(X08-)(B/2)
YES
TP49
TP48
+15V
+15V
+15V
+15V
-15V
-15V
-15V
-15V
0.01
C122
TP21
0.01
C104
15K
R126
TP43
TP42
TP38
2.2K
R122
TP45
TP22
TP30
TP29
100P
C126
8.2
R129
47K
R102
-15V
TP37
+
+
CAUTION : For continued safety, replace safety critical
components only with manufacturer’s recommended parts
(refer to parts list).
Indicates safety critical components. To reduce the risk of
electric shock, leakage-current or resistance measurements
shall be carried out (exposed parts are acceptably insulated
from the supply circuit) before the appliance is returned to the
customer.
• DC voltages are as measured with a high impedance
voltmeter. Values may vary slightly due to variations
between individual instruments or/and units.
B
C
E
2SA992-A
2SC1845-A
2SA1576A
2SC4081
DTA114EUA
DTC114EUA
DTC124EUA
BA10358F