![Kenwood GX-201KEF2 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/kenwood/gx-201kef2/gx-201kef2_service-manual_188637005.webp)
5
GX-201KEF2/LEF2/REF2/SEF2
Ref. No.
Application / Function
Operation / Condition / Compatibility
Q802
Illumi detection
For illumi detection
Q803
Reset output switch for F-BUS
When resetting F-BUS, Hi output
Q804
NAVI mute switch
When muting NAVI, Hi output
Q805
IF count detection
When detecting IF count, Lo output
Q806
P-ANT circuit control switch
When tuner, GND electric potential output
Q807
ACC detection
When ACC ON detection, Lo output
Q808
IGN detection
When IGN ON detection, Lo output
Q809
SYS_ON current buffer
When SYS_ON Hi, Lo output
Q810
Hard reset switch
When HARD_RESET ON, Lo output
Q812
BUS_OFF switch
When F-BUS system OFF, Hi output
Q813
P-ON5V power supply switch
For P-ON5V
Q815
BU detection
When BU ON, Lo output
Q816
P-ANT circuit control switch
When tuner, BU electric potential output
Q817,818
P-ANT circuit protection
P-ANT short circuit protection
Q820
F-BUS mute output
When mute ON, Hi output
Q821
BUS_ON detection
When F-BUS system ON, Hi input
Q822
BUS_ON switch
When F-BUS system ON, Hi output
Q850,852
Illumination - detection switch
When detecting illumination -, Hi output
Q853
Illumination - detection switch
When detecting illumination -, Lo output
●
SWITCH UNIT (X25-929x-xx)
Ref. No.
Application / Function
Operation / Condition / Compatibility
IC1
Display control
µ
-com
VFD control, Key intake
For bug counter-measures
When audio VFD ON, 5V output
When audio DC/DC ON, Lo output
When heater VFD ON, 5V output
When heater DC/DC ON, Lo output
F differential indicator power supply switch
When F-differential indicator ON, 5V output
R differential indicator power supply switch
When R-differential indicator ON, 5V output
Multiple-push reset circuit detection
When detecting REP/RDM, DWN_SEEK, Hi output
Q22
Multiple-push reset circuit detection
When resetting by multiple push, Lo output
Q23
Multiple-push reset circuit detection
When TONE (BAL/FAD) detected, Lo output
Q24
Heater UART communication control
Heater UART communication control (TX)
Q25
Heater UART communication control
Heater UART communication control (RX)
Q26
SW5V power supply switch
When IGN ON, 5V output
Q27
Panel illumination switch
When panel illumination ON, 10V output
COMPONENTS DESCRIPTION
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299