![Kenwood DVR-605 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/kenwood/dvr-605/dvr-605_service-manual_191840024.webp)
BI
BK
BM
BJ
BL
DVR-605
Y39-4480-10
S833
S834
MENU
D803
SHIFT
REGISTER
P802
P812
D838
Q836
D831
D830
Q831
Q833
Q834
Q832
Q835
D833
DTS
D835
CS-51
D834
D836
D837
DOLBY
DIGITAL
PROLOGIC
IC81
: BU4094BF
Q831-835 : DTC114YKA
Q836
: DTA114YKA
D802-804 : UDZ5.1
D830
: 1SS355
D831,832 : 1N4148
D833-838
B30-2638-08
:
STOP
S835
PLAY/
PAUSE
INPUT
S838
S836
S837
MENU
TOP
CINEMA
EQ
ENTER
DSP
1.5K
2.2K
1
2
3
4
5
6
7
8
ST
DATA
CLK
Q1
Q2
Q3
Q4
VSS
16
15
14
13
12
11
10
9
VDD
ENABLE
Q5
Q6
Q7
Q8
Q'S
QS
C834 100P
100P
C835
6
7
1
2
1
2
180
100
R837
0.01
C832
R853
100K
1u50
C839
+
7
11
6
12
13
180
R841
R843
180
180
R842
R844
180
180
R845
D837
D833
D836
D835
+B
+5.5V
+5.5V
+5.5V
29
NP
43
42
41
F2
F2
F2
NP
40
39
38
37
36
35
P17
P18
P19
P16
P15
P17
P19
P18
P16
P15
34
33
32
31
30
P14
P13
P12
P10
P8
P11
P14
P13
P12
P11
P10
P8
7
18
P3
P3
28
27
26
25
24
P6
P7
P9
P4
P5
P6
P9
P7
P5
P4
22
22
21
20
19
P2
P1
P2
P1
NX
NX
NX
8G
8G
17
16
15
14
13
11G
9G
10G
11G
NX
NX
10G
9G
12
11
10
6G
7G
3G
5G
4G
7G
6G
5G
4G
3G
9
8
F1
F1
2G
1G
4
2G
1G
NP
6
5
NP
F1
3
2
1
R846
13
12
11
R850
R851
R855
5.6K
R852
2.7K
R854
3.3K
1.5K
R806
R811
2.2K
D834
DP81
IC81
LED B'D
STANDBY
FRONT B'D
DVR-605 (4/4)
3G
4G
5G
1a
a
g
d
fb
ec
2a
1a
2a
1a
2a
1a
1a
2a
j
col
j
j
j
n
n
n
h
6G
(1G-5G)
2G
1G
col
Dp
Dp
P1
2G
3G
5G
4G
6G
DVD
1G
P2
P3
P5
1b
1b
1b
1b
1b
P4
1a
1a
1a
1a
1a
P8
1h
1n
1n
col
col
1n
P9
P7
1e
1e
1f
1f
1d
1d
P6
1c
1c
2
1
SEQ.
2g
Dp
Dp
1
DISC
RANDOM
2g
P17
P16
P14
P15
PCB
P12
P13
P11
2f
2f
2d
2e
2d
2e
2b
2b
2c
2c
2g
2f
2d
2e
2b
2c
2g
2j
INTRO
2j
2f
2d
2e
2b
2c
2a
2a
2a
2a
P10
1g
1g
1e
1e
1f
1f
1d
1d
1c
1c
1g
1e
1f
1d
1c
1g
1g
P20
(3)
(5)
PROG.
ALL
S
P19
P18
VCD
HOUR
TITLE
CHAP
TRACK
MIN
SEC
C D
REPEAT
MP3
A
B
P21
(2)
(4)
P22
3
(1)
1
5
P23
2
4
CAUTION:
For continued safety, replace safety critical com-
ponents only with manufacturer's recommended parts (refer
to parts list).
indicates safety critical components. For
continued protection against risk of fire, replace only with
same type and rating fuse(s). To reduce the risk of electric
shock, leakage-current or resistance measurements shall be
carried out (exposed parts are acceptably insulated from the
supply circuit) before the appliance is returned to the cus-
tomer.
The DC voltage is an actual reading measured with a high
impedance type voltmeter with no signal input. The mea-
surement value may vary depending on the measuring
instruments used or on the product.