17
DPX701/701U/701UY
DPX-MP7090U
• By pressing [AUD] or [FM] key briefly, switch the item to be
adjusted in the following order. (only in forward rotation)
The initial item will be Fader, which is followed by : Balance
→
Bass Level
→
Middle Level
→
Treble Level
→
HPF Front
→
HPF Rear
→
LPF Sub Woofer (After this, it will be arbi-
trary)
• With the remote controller, continuous forwarding is pro-
hibited.
• Using the VOL knob and [
] / [
] key, the Fader can be
adjusted in 3 steps : R15
↔
0
↔
F15 (The initial value is 0)
• Using the VOL knob and [
] / [
] key, the Balance can
be adjusted in 3 steps : L15
↔
0
↔
R15 (The initial value is 0)
• Using the VOL knob and [
] / [
] key, the Bass / Middle
/ Treble Level can be adjusted in 3 steps : –8
↔
0
↔
+8
(The initial value is 0)
• Using the VOL knob and [
] / [
] key, the HPF Front /
Rear can be adjusted in 2 steps : Through
↔
220Hz (The
initial value is Through)
• Using the VOL knob and [
] / [
] key, the LPF Sub
Woofer can be adjusted in 2 steps : 50Hz
↔
Through (The
initial value is Through)
• Using the VOL knob and [
] / [
] key, the Sub Woofer
Phase can be adjusted in 2 steps : Reverse
↔
Normal (The
initial value is Normal)
• Using the VOL knob and [
] / [
] key, the Volume Off-
set can be adjusted in 2 steps : –8
↔
0 (The initial value is
0)
• Using the VOL knob and [
] / [
] key, the Loudness
ON/OFF can be adjusted in 2 steps : OFF
↔
ON (The
initial value is OFF)
• Using the VOL knob and [
] / [
] key, 2-Zone ON/OFF
can be adjusted in 2 steps : OFF
↔
ON (The initial value is
OFF)
• Bass f / Bass Q / Bass EXT / Middle f / Middle Q / Treble f
do no appear in audio adjustments.
●
MENU items
• Press [Q] key briefly to enter the MENU.
• The [DNPP/SBF] and [DIRECT] keys on the remote con-
troller can also be used to enter the MENU.
• With the remote controller, continuous forwarding is pro-
hibited.
• When a CD/USB is used as a source, the default item will
be the F/W Version.
●
2-ZONE (Dual Zone) items
• When using sources other than the STANDBY source, us-
ing a short-press on [AUTO] or [TI] key, 2-ZONE ON/OFF
is achieved.
●
Backup current measurement
When reset in Acc OFF (Back Up ON) condition, MUTE termi-
nal goes off after 2 seconds, instead of 15 seconds. (During
this time, the CD mechanism does not function.)
●
OPEL communication items (OPEL communica-
tion specification supporting model)
During the test mode, OPEL communication line outputs the
following (At every 500msec, the output condition of the com-
munication line will be switched.)
●
G sensor display items (G-Analyzer supporting
model)
When source is STANDBY, by short-pressing [ATT] key, the
display is switched to analogy meter display, in which vertical
G and horizontal G are displayed.
●
Special display when all lights are on
When all lights are on with the STANDBY source, the follow-
ing displays are made when the keys shown below are pressed.
[1] key
Version display
(Display) C0528WK__SYS1. 23
(Display) STYPE : x__PAN1.11
(Display) PTYPE : x__MEM3.21
∗
STYPE indicates system
µ
-com destination, and PTYPE
indicates panel
µ
-com destination, and show real-time
condition of the destination terminal (“x” is displayed in
hexadecimals.)
[2] key
Serial number display (8 digits)
(Display) SNo_xxxxxxxx
[3] key
Key pressed briefly : Power ON time is displayed.
(Display) PonTim_0Hxx_ (00~50 is displayed for “xx”.
When less than 1 hour, displayed
by increments of 10 minutes.)
xxxxx (00001~10922 is displayed for
“xxxxx”.) MAX 10922 (times)
During Power On time display, by pressing for at least 2
seconds, the Power ON time is cleared.
CE
DATA
CLK
500msec
500msec
500msec
TEST MODE