41
CONNECTING THE FEEDER CABLE
To connect the feeder cable to the cooker
it is necessary to:
– Remove the two screws that hold
shield A behind the cooker.
– Open completely the cable clamp D.
– Insert the mains cable (type H05 RR-
F) of minimum 6 mm
2
section into the
cable clamp D.
– Connect the phase and earth cables to
terminal B according figure 8.2 and
8.3.
– Pull the feeder cable and block it with
the cable clamp D
– Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
A
D
B
Fig. 8.1
PE
1 2 3 4 5
N (L
2
)
L
1
230 V
Fig. 8.2
FEEDEER CABLE SECTION
“TYPE H05RR-F”
230 V
3 x 6 mm
2
(**)
(**) – Connection with wall box connection.
– Contemporaneity factor applied
2
3
4
5
1
230 V ~
N(L
2
)
PE
L1
Red
or
Brown
(Live)
Black
or
Blue
(Neutral)
Green
and
Yellow
(Earth)
Fig. 8.3
PE Earth
N
Neutral
L
Live