38
Fig. 11.1
D
B
PE
A
N
L
FEEDER CABLE SECTION TYPE
HO5RR-F
230 V
3 x 2,5 mm
2
230 V
PE
N
L
1
(L
2
)
Fig. 11.2
PE
Earth
N
Neutral
L
Live
TECHNICAL DATA
230 V AC - 50 Hz
Fan Main oven
– Grill element
2.00 kW
– Circular element
2.50 kW
Conventional oven
– Top element
0.70 kW
– Bottom element
0.80 kW
– Grill element
1.45 kW
Maximum power rating
– Fan oven
2.50 kW
– Conventional oven
1.50 kW
Oven lamp
0.015 kW
300 °C, miniature edison screw
Fan motor
0.025 kW
Maximum power
usable simultaneusly
4.085 kW
ELECTRICAL FEEDER CABLE
CONNECTION
To connect the supply cable:
- Remove the screws securing the
cover “
A
” on the rear of the cooker
(fig. 11.1).
- Feed the supply cable through the
cable clamp “
D
”. The supply cable
must be of a suitable size for the
current requirements of the appliance;
see the section “Feeder cable
section” .
- Connect the wires to the terminal
block “
B
” as shown in the diagram in
figure 11.2; or connect the phase
wires to the terminal block “
B
” and
the earth wire to the terminal PE as
shown in figure 11.1.
- Take up any slack in the cable and
secure with the cable clamp “
D
”.
- Replace the cover “
A
”.
N.B.
The earth conductor must be left