32
Gas Connection
GB
Cat: II 2H3+
The gas supply must use the nearest gas inlet pipe which is located at the left or the right
hand side at the rear of the appliance (fig. 9.1).
The hose should also be connected in such away that it does not touch the floor.
To screw the connecting tube operate with two spanners (fig. 9.2).
The unused end inlet pipe must be closed with the plug interposing the gasket .
After connecting to the mains, check that the coupling are correctly sealed, using
soapy solution, but never a flame.
Plug
Left gas
inlet pipe
Right gas
inlet pipe
Fig. 9.1
Gasket
Fitting the 1/2” BSP
(male) connector
The male
connector is
already
fitted on the left
or right inlet pipe
1/2” BSP (male)
Fitting the plug on the
inlet pipe terminal not used
Cooker manifold
(Right or left
inlet pipe)
Manifold
male pipe fitting
Gasket (#)
Plug (#)
(#) Already fitted on the
right or left inlet pipe
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) female
Fig. 9.2