![Kenwood CK 300 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/kenwood/ck-300/ck-300_instructions-for-use-manual_190857038.webp)
38
Fig. 10.10
Ring opening
Fig. 10.11
Ring opening
REGULATION OF AIR SUPPLY TO OVEN AND GRILL BURNERS
Using a cross-head screwdriver, slacken the screw securing the air flow regulation collar
(fig. 10.10 and 10.11) and move the collar forward or backward to increase or reduce
the air aperture in accordance with gas type and the indications in the “TABLE FOR
THE CHOICE OF THE INJECTORS”.
Light the burner and check the flame.