CD-3260M/3280M/DPF-J7020
9
CIRCUIT DESCRIPTION
INPUT KEY
PROCEDURE
DISPLAY
UP
Arm Motor Load operation.
MOTOR LOAD
DOWN
Arm Motor Unload operation.
MOTOR UNLOAD
RANDOM
Rotary Motor Clockwise turning.
MOTOR CW
DISPLAY
Rotary Motor Counterclockwise turning.
MOTOR CCW
POWER
Check the transmission signal(Disc No.1 and Track
No.99) of the remote controller.
*DPF-J7020 only
REPEAT
Playback PGM signal of the Track No.1,23 and 41 in the order.
And release the test mode.
CONFIRM
Release the test mode.
(TIMER PLAY SW)
Check the switch position.
TIMER ON , TIMER OFF
(SL16/XS8 SW)
Check the switch position.
16BIT, 8BIT
DISPLAY
ERROR CONTENTS
MECHA ERROR 01
No input of S3. The original position error of Disc Number.
MECHA ERROR 02
No input of S2. The turning direction error to counterclockwise
MECHA ERROR 03
No input of S1. The turning direction error to clockwise
MECHA ERROR 04
No input of main load sw.
MECHA ERROR 05
No input of main unload sw.
MECHA ERROR 06
No input of sub load sw.(CD-3280M)
MECHA ERROR 07
No input of sub unload sw.(CD-3280M)
MECHA ERROR 08
No backed up(AC power cord has disconnected).
4. Error code
S1-3:Mechanism address detector switch.
There are load and unload switches in the main pickup.
S3
S2
SENSOR PCB
S1 DISC 1~9
S2 DISC 10~99
S3 DISC 100~200
S1
CD-3260M(K)
COVER1,1(
99.10.29
9:11
AM
y [ W 18