![Kenwood A64-4718-02 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/kenwood/a64-4718-02/a64-4718-02_service-manual_188349017.webp)
17
KDC-MP442U/MP6043U
/W5544U/W5644UY/X493
■
MENU-related test mode
* In the TUNER source, run the unit in the normal operation (PRESET call operation) mode.
Procedure
Note
Press [SEARCH] key brie
fl
y (Unit itself)
Press [DNPP/SBF] key and [DIRECT] key brie
fl
y (Remote controller)
Continuous forwarding by remote control is prohibited
■
Backup current measurement
Procedure
Note
While ACC OFF (Back Up ON), Reset
MUTE terminal is OFF after 2 seconds, not after 15 seconds.
(During this time, the CD mechanism does not function.)
■
Switching of Preout
Procedure
Note
Press and hold [TI/AUTO] key in the Standby source
Switching PREOUT
■
Clearing of CD mechanism information, Service information, DC offset error information, and FAVOR-
ITE registration information. (Clear the data recorded in FLASH MEMORY of E2PROM)
Status
Display
Description
Resetting while [TI/AUTO] + [FAV] is be-
ing pressed
C
D
O
At normal termination
C
D
X
At abnormal termination
While “– – – –” is displayed, power can be ON. This mode is cancelled by resetting. (The last screen will not be retained.)
Data to be cleared is shown below.
Information to be cleared
Details of information
Data recorded in
CD mechanism informa-
tion
CD mechanism error log display
E2PROM
Displays CD loading error data
E2PROM
Displays CD EJECT error data
E2PROM
Displays CD time code count error data (missing count)
E2PROM
Displays CD time code count error data (count not updated)
E2PROM
Service Information
Power ON time display
E2PROM
CD operation time display
E2PROM
CD EJECT times display
E2PROM
PANEL open/close times display
E2PROM
Forced Power OFF information display
E2PROM
DC offset error informa-
tion
DC offset error 1 display (Provides information on whether there is an improper
connection or another error)
E2PROM
DC offset error 2 display (Provides information on the number of capacitor leaks)
E2PROM
FAVORITE registration
information
FAVORITE registration information (Registration list)
* Total 10 items
E2PROM
TEST MODE