background image

10

 

P 40    

 Continue = start  - (default: off) 

 

The following can be selected: 
Off  

[oFF] 

On 

 

[  on] 

- when set to on, all continue messages are treated as if they were MIDI start messages. 
- when set to off, continue messages will only be treated as start if immediately preceded by a song 
position pointer = zero message.  Some sequencers use this instead of a start message. 
Affects both the sync 24 output and aux output when in clock mode. 
 

P 41   

Clock divide ratio - (default: 2)

 

  
available values c24, c48 & d2 to d24, 
- sets the ratio of MIDI clocks to output pulses from the aux3 output set to clock mode 
 

c24

 – special drum machine mode – outputs 24 cpqn – used for many drum machines  

c48

 – special drum machine mode – outputs 48 cpqn – for Linn & Oberheim drum machines 

N.B. Some drum machines use other values e.g. the Roland CR78 uses 12 cpqn (div ratio 2) 
 
If set to 2, there will 12 pulses from the aux output for every 24 MIDI clocks = 12 cpqn 
If set to 24, there will be 1 pulse from the clock pulse output for every 24 MIDI clocks = 1 cpqn 
(Note there are 24 MIDI clocks per quarter note) 
 
Below is a table of values you can set the divide ratio to in order to obtain a clock pulse at various 
musical time intervals:- 
 
Note type 

 

 

 

Divide ratio 

 

CPQN (clocks per quarter note)

 

 

Crotchets 

(quarter notes)                24                                   1 

 

Crotchet triplets                                        16 
Quavers 

  (eighth notes)   

12                                   2 

Quaver triplets                               

  8 

Semiquavers 

      (sixteenths)               6                                   4 

Semiquaver triplets                               

  4                                   6 

Demisemiquavers                                     3                                   8 
Demisemiquaver triplets                       

  2                                 12 

 

P 42   

AUX 2 controller number (default: 18) 

 

- Sets which MIDI controller will control AUX2 output 
The following controllers can be selected: 
 
Clock Stop/Start 

[S t t] 

Off 

  [oFF] 

Pitch bend 

 

[Pbd] 

Velocity 

  [VEL] 

Aftertouch  

[AF 

t] 

MIDI controllers  

0-119 

 
Note that this is a switch output and will be 0 volts or 5 volts depending on the MIDI data value and the 
threshold setting below. 

 

P 43   

AUX 2 threshold (default: 64) 

 

Range   

1 to 127 

- Sets the threshold at which the AUX2 output will change from 0 to 5V or from 5V to 0. 

 

If the MIDI data value of the selected controller is greater than or equal to the threshold then AUX2 will 
be on (5V), otherwise it will be off (0V). 

 

Note: Does not affect Clock Stop/Start

Содержание USB SOLO

Страница 1: ...U U U US S S SB B B B S S S SO O O OL L L LO O O O USB Single channel MIDI CV converter Operating manual...

Страница 2: ...nterference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television...

Страница 3: ...g MIDI controllers Velocity mod wheel etc Note not all mono synths have such additional control inputs AUX2 digital aux out Use this to control switchable inputs Signal is either zero or 5V AUX3 clock...

Страница 4: ...e displayed Minus values up to 127 or positive values up to 255 are used The display will automatically revert to parameter mode after approximately 10 seconds if neither inc or dec are pressed The va...

Страница 5: ...the newest valid note played takes precedence The USB SOLO has a 5 note buffer memory so that trill effects can be achieved P 04 Pitchbend range default 2 Range 0 to 12 semitones The pitch bend range...

Страница 6: ...at minimum can be set above maximum so that the controller works backwards Why would I want to do this The modulation amount at mod wheel maximum may be too great or too little P 11 LFO to CV reset va...

Страница 7: ...d SCI ARP Oberheim The low level gate may be needed for synths that require a lower gate voltage such as the SH 101 S trig no pull up S 00 This would be used for most Moogs Korgs and some Yamaha synth...

Страница 8: ...17 Sets which Controller will control the LFO depth applied to the AUX1 output The following can be selected Off oFF Pitch bend Pbd Velocity VEL Aftertouch AFt MIDI controllers 0 to 119 P 26 LFO to A...

Страница 9: ...set for see below for divide ratios A divide ratio can be set so the LFO only re triggers every so many MIDI clock messages MIDI sends 24 clocks per quarter note So if divide is set to 1 there will be...

Страница 10: ...ulse output for every 24 MIDI clocks 1 cpqn Note there are 24 MIDI clocks per quarter note Below is a table of values you can set the divide ratio to in order to obtain a clock pulse at various musica...

Страница 11: ...with no adjustment necessary One intended use for Auxes 2 3 is to control the accent slide of our 5 socket kit for the TB 303 If you are not using a sequencer you will need some way of linking your MI...

Страница 12: ...Parameters mode displays GPA decribed below INC only Displays the firmware revision number described below SEL DEC Powers up without USB from plugging cable in only displays NoU SEL INC Receive firmw...

Страница 13: ...selected the USB SOLO will display the value it receives for the type of message currently selected Although pitchbend and after touch are not strictly controllers when Controller number Cn mode is s...

Страница 14: ...ock problems on our website in the Information and FAQs section Clock Stop Start signal is available at the Aux 2 output if selected as the controller source Para 42 Clock with a rate of between 1 and...

Страница 15: ...he synth it will not always be clear what type of CV and GATE signals are required to play the synth For instance the Korg MS20 requires an S TRIG signal but the input is labelled TRIG Another example...

Страница 16: ...output into the external control input of the synth e g Filter input the cut off frequency can be controlled over MIDI The AUX output is not controlled by MIDI note numbers The converter allows you t...

Страница 17: ...r pedal sustain Hold 1 65 41H Portamento 66 42H Sostenuto 67 43H Soft pedal 68 44H Undefined 69 45H Hold 2 70 79 46 4FH Undefined 80 83 50 53H General purpose controllers 5 8 84 90 54 5AH Undefined 91...

Страница 18: ...h low 7 bits of parameter address 10 0uuuuuuu where uuuuuuu high 7 bits of data either 0 or 1 for usb solo 11 0hhhhhhh where hhhhhhh low 7 bits of data 12 0F7h end of exclusive The USB SOLO responds b...

Страница 19: ...et value 0 127 25 Lfo speed 0 191 26 Lfo waveshape 0 8 7 27 Lfo MIDI sync 0 96 8 28 Lfo sync start point 0 255 29 Key on resets LFO wave 0 1 10 30 cont start 0 1 11 31 clock divide 0 24 9 32 Aux 2 con...