RECOVERY WATER SYSTEM
SERVICE MANUAL
ENGLISH
Razor™ 20 / 20T
9097065000(2)2009-06
21
RECOVERY WATER SYSTEM
RECOVERY WATER TANK AND VACUUM GRID CLEANING, AND COVER GASKET CHECK
Drive the machine to the appointed recovery water disposal area.
1.
• (For Razor™ 20T) Turn the ignition key (80) to “0”.
2.
(For Razor) Turn off the switches (71) and (73).
•
Lift the cover (A) to washing position (L).
3.
Wash with clean water the cover (A), the tank (B) and the vacuum grid with automatic shut-off loat (D).
4.
Drain the water in the tank through the hose (16).
If necessary, release the fasteners (E) and open the grid (D), recover the loat (F), clean all the components and then reinstall
5.
them.
Check the tank cover gasket (G) for integrity.
6.
NOTE
The gasket (G) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (G) by removing it from its housing (H). When assembling the new gasket, install the
joint (I) in the rear central area, as shown in the igure.
Check that the bearing surface (J) of the gasket (G) is integral and adequate for the gasket itself.
7.
Check the compensation hole (K) for clogging, and clean it if necessary.
8.
NOTE
The hole (K), allowing to compensate the air in the cover interspaces, contributes to create vacuum in the tank.
Close the cover (A).
9.
H
D
E
E
F
G
C
B
J
A
G
L
I
K
P100142