Note: Filters and membrane are consumables. Their replacement time is dependent on the quality of raw
water and water consumption. They are not covered under the warranty. However, if a filter chokes within
six months and a membrane within a year, it will be cleaned/repaired/replaced free of cost. Changing the
filters and system inspection is available on call. The treatment capacity of RO membrane will reduce with
time due to clogging of pores of membranes.
“This reverse osmosis system contains a replaceable component critical to the efficiency of
Replacement of the reverse osmosis component should be with one of identical specifications as
defined by the manufacturer, to ensure the same efficiency and contaminant reduction
performance.”
The reverse osmosis system contains a replaceable treatment component critical for the effective
reduction of total dissolved solids and that product water shall be tested periodically to verify that the
system is performing properly.
Replacement of spare parts are as under:-
Maintenance
8
-20010
SP Inline Sediment Filter 8”
-20009
SP Inline Carbon Block Filter 8”
-20002
SP RO Membrane Welded 8” Housing
-20015
SP Post Carbon Filter (Blue)
-20003
SP Hollow Fibre Membrane (GPMRO)
7
n
n
n
n
n
n
Switch on the power supply
so as to remove any dust particles present in
the pipes and storage tank
Wait till the storage tank fully fills up
Close the drain plug and switch on the power
Switch off the power supply
supply
Drain the storage tank by opening the drain
plug present at the bottom of the storage tank
The purifier is ready to use
Starting Up the Purifier
5.
6.
7.
(I)
(ii)
Now connect one end of the white pipe to the SS ball valve and other end
to the lower pushfit elbow fitting on the left hand side of the purifier
labeled as WATER IN. (Note : White pipe is for raw water supply)
Similarly, connect one end of the blue pipe to the upper elbow fitting
connector labeled as REJECT WATER and leave the other end in the
drain. (Note : Blue pipe is for reject water)
Before connecting the power supply, it is important that you perform the
following functions:
Open the SS ball valve (Handle parallel to the ball valve) to start the
flow of water into the purifier.
Wait for 2-3 minutes to ensure that the filters are soaked in water.
TM
A unique feature in
Prime TC Mineral RO
screw of the valve anticlockwise; it will result in
Water Purifier is the TDS control valve, which is not
more mineral content in treated water. To reduce
available in any other domestic water purifier till
the TDS level, user can turn the screw valve
date. This feature allows the user to control the
clockwise, it will result in less mineral content in
content of natural minerals (TDS) in purified treated water. We recommend the TDS of the
water .
purifier to be kept at lowest but not below 50
mg/l.
To increase the TDS level the user can turn the
KENT
TDS Adjustment
Although the rejected water has high
of salts and minerals which accelerate plant
concentration of salts. This rejected water usually
growth. Rejected water can also be used for
goes down the drain, but if required, can be used
cleaning purposes, i.e. utensils cleaning,
for gardening purposes. It has high concentration
mopping, etc.
Recommended Uses of Rejected Water
or after every 12 months. It is recommended to
To ensure that the purifier operates at its optimum
level, a routine maintenance must be performed.
change the FRT when the filters are replaced
The frequency of the maintenance will greatly
Replace the RO membrane once in 2 years
depend upon the raw water quality and
consumption of treated water
Replace the UV Lamp once in 2 Years
Storage tank must be drained once in 2 weeks.
If you are not going to use the purifier for a
To do so, switch off the power supply, open
long time ( in case you are on a holiday, tour or
the drain plug at the bottom of the tank and
out of home), make sure that you disconnect
allow the water to drain. Then screw back the
the power supply, turn off the raw water
plug and switch on the power supply
supply and drain the storage tank
Replace sediment, activated carbon and post
carbon when the filter change alarm is audible