KENT MAXX ALKALINE Скачать руководство пользователя страница 5

Installation Instructions

To ensure purer water throughout the service cycle, KENT MAXX ALKALINE is equipped 

with an in-built UV Fail Alarm which gets activated in the event of UV lamp failure. In 

case the UV lamp malfunctions, the purification process automatically stops and the 

purifier starts emitting a short beep at an interval of every 2 seconds.

UV Fail Alarm

Under such circumstances, please switch off the purifier and call the service technician 

for help. The purifier will stop purification in such a situation. 

KENT MAXX ALKALINE

 

has an in-built feature that makes an alarm sounds to indicate 

the replacement time of filters. This alarm is audible after 700 hrs of filter use. The 

Filter Change Alarm works as follows: 
Gives 4 short beeps every two seconds, lasting upto 30 seconds. The alarm gets 

activated after every 2 hours of use.

Filter Change Alarm

Under such circumstances, the purifier will not function unless the filters are changed.

2 Sec.

2 Sec.

2 Sec.

2 Sec.

30 Sec.

30 Sec.

Slot holes

   Computer Controlled Operation

6

5

KENT MAXX ALKALINE is a convenient and easy-to-install wall mounting model.

Recommended Site Preparations:

 Single Phase 140-250 V AC, 50-60 Hz. supply not more than 3 m away from the 

point of installation

  Raw water supply with ½ inch nipple not more than 3 m away

  Installation space as per the dimensions of the purifier

  Wall/plane surface for mounting screws and holding the machine.  Avoid installation 

on wooden and metallic stands

  For optimum inlet pressure, the source water tank should be at least 10ft above the 

purifier installed

  Install the purifier near a sink for easy availability of inlet water lines

  The system and installation must comply with applicable state and local laws & 

regulations

Installation Procedure:

1.  Screw in two 10x50 self taping screws, 3.95 (100 mm) apart horizontally.
2. Wall-mount the purifier with the help of the slot holes given on the back.

3.  Fasten the SS ball valve to ¼ inch port of 3-way connector.

4.  Attach the threaded end of the 3-way connector to the raw water 
 

supply and plug off the other end or connect to a tap.

5.  Now connect one end of the pipe to the SS ball valve and other end to the elbow fitting  

 

 

connector labeled as WATER IN, on the left side of purifier.

6.  Turn on the lever given on the SS ball valve to initiate water flow to the purifier. 

To ensure the delivery of purer and healthier water, a micro processor is installed in the 

purifier to perform the following functions:-

UV Stabilisation Delay:

 To ensure that the UV lamp is pre-heated and is working at its 

optimum before it starts disinfecting water, the controller provides a two second delay to 

the UV lamp when a purifier is switched on. During this period, only the UV lamp is on 

and all other electrical devices of the purifier are switched off and no water flows 

through.

Purification Delay:

 To ensure that the water lying idle in the internal pipes and the UV 

chamber is thoroughly disinfected before being passed onto the storage tank, the 

system provides approximately 5 seconds of Purification Delay when the purifier is 

switched on. During this period, all electrical devices except the UV lamp are switched 

off and the UV lamp kills the micro organisms present in the water inside the UV 

chamber. After this delay, all other electrical devices such as solenoid valve etc., get 

activated and the normal purification process starts.

Audible Alarm:

 The microprocessor  also controls the activation of the UV Fail Alarm 

and Filter Change Alarm.

Please call the service technician once the Filter Change Alarm is activated and get the 

filters replaced. In case the filters are not replaced within the next 60 hours of 

operation, the purifier stops functioning to avoid the delivery of impure water and beeps 

continuously. 