Installation Instructions
To ensure purer water throughout the service cycle, KENT MAXX ALKALINE is equipped
with an in-built UV Fail Alarm which gets activated in the event of UV lamp failure. In
case the UV lamp malfunctions, the purification process automatically stops and the
purifier starts emitting a short beep at an interval of every 2 seconds.
UV Fail Alarm
Under such circumstances, please switch off the purifier and call the service technician
for help. The purifier will stop purification in such a situation.
KENT MAXX ALKALINE
has an in-built feature that makes an alarm sounds to indicate
the replacement time of filters. This alarm is audible after 700 hrs of filter use. The
Filter Change Alarm works as follows:
Gives 4 short beeps every two seconds, lasting upto 30 seconds. The alarm gets
activated after every 2 hours of use.
Filter Change Alarm
Under such circumstances, the purifier will not function unless the filters are changed.
2 Sec.
2 Sec.
2 Sec.
2 Sec.
30 Sec.
30 Sec.
Slot holes
Computer Controlled Operation
6
5
KENT MAXX ALKALINE is a convenient and easy-to-install wall mounting model.
Recommended Site Preparations:
•
Single Phase 140-250 V AC, 50-60 Hz. supply not more than 3 m away from the
point of installation
•
Raw water supply with ½ inch nipple not more than 3 m away
•
Installation space as per the dimensions of the purifier
•
Wall/plane surface for mounting screws and holding the machine. Avoid installation
on wooden and metallic stands
•
For optimum inlet pressure, the source water tank should be at least 10ft above the
purifier installed
•
Install the purifier near a sink for easy availability of inlet water lines
•
The system and installation must comply with applicable state and local laws &
regulations
Installation Procedure:
1. Screw in two 10x50 self taping screws, 3.95 (100 mm) apart horizontally.
2. Wall-mount the purifier with the help of the slot holes given on the back.
3. Fasten the SS ball valve to ¼ inch port of 3-way connector.
4. Attach the threaded end of the 3-way connector to the raw water
supply and plug off the other end or connect to a tap.
5. Now connect one end of the pipe to the SS ball valve and other end to the elbow fitting
connector labeled as WATER IN, on the left side of purifier.
6. Turn on the lever given on the SS ball valve to initiate water flow to the purifier.
To ensure the delivery of purer and healthier water, a micro processor is installed in the
purifier to perform the following functions:-
UV Stabilisation Delay:
To ensure that the UV lamp is pre-heated and is working at its
optimum before it starts disinfecting water, the controller provides a two second delay to
the UV lamp when a purifier is switched on. During this period, only the UV lamp is on
and all other electrical devices of the purifier are switched off and no water flows
through.
Purification Delay:
To ensure that the water lying idle in the internal pipes and the UV
chamber is thoroughly disinfected before being passed onto the storage tank, the
system provides approximately 5 seconds of Purification Delay when the purifier is
switched on. During this period, all electrical devices except the UV lamp are switched
off and the UV lamp kills the micro organisms present in the water inside the UV
chamber. After this delay, all other electrical devices such as solenoid valve etc., get
activated and the normal purification process starts.
Audible Alarm:
The microprocessor also controls the activation of the UV Fail Alarm
and Filter Change Alarm.
Please call the service technician once the Filter Change Alarm is activated and get the
filters replaced. In case the filters are not replaced within the next 60 hours of
operation, the purifier stops functioning to avoid the delivery of impure water and beeps
continuously.