KENT Gold+ Скачать руководство пользователя страница 6

Part 1: Cleaning the UF Membrane

Open the box and remove the parts. Tally the contents with the 'Items 
in the Box' list (page no. 1). Wash all the plastic parts with clean water 
and wipe  dry  with  a  clean  cloth  before  assembling.

l

Once assembled, fill the inner tank with water. Wait till the filtration 
is  complete

l

Drain the water collected in the Outer Tank, initially. This water should 
be  drained  even  if  all  parts  have  been  washed  thoroughly  before 

installation

l

Refill the Inner Tank when empty

l

To refill the purifier, twist the Top Lid and remove it. Pour the raw water 
slowly  into  the  Inlet  Funnel,  ensuring  that  water  does  not  spill

l

After filling the Inner Tank, close the Top Lid

1

2

3

10

12

Take 50 ml of pure water in the 

syringe and inject it into the  

Membrane Cartridge (opposite to 

the direction of flow) to soak the 

new membrane

Push-fit the UF Membrane by 

pressing into the fitting of 

the Inner Tank. 

NOTE: Be careful to insert the 
UF Membrane opposite to the 

direction of water flow.

6  KENT RO SYSTEMS LTD.

+

Gold  Installation Manual  7

Fequency

l

The UF Membrane should be cleaned at least once in a month. However, if the water flowing from 

Inner Tank  to  the  Outer  Tank  reduces  sharply,  Membrane  can  be  cleaned  even  earlier

l

It is essential to change the UF Membrane once in a year

Remove the Inner Tank

Turn the Inner Tank upside down

Place it on a horizontal surface; 

Take 50 ml of pure water in the 

given syringe. Fit the syringe into 

the opening of Membrane 

Cartridge and slowly inject water 

from syringe into the cartridge 

(back-flushing). Perform this step 

once. Repeat if required.

3

2

1

Assemble the Tap on the

Outer Tank

Place the Bottom Stand on 

a flat surface

Place the Outer Tank above the 

Bottom Stand

Place the Inner Tank with UF 

Membrane on the Outer Tank

5

6

4

8

9

Place the Top Cover on the 

assembled tanks

Before Installing the Filter Assembly, 

wash it under a running tap. Shake, 

if required, to remove Carbon 

particles from the new Filter

Place the Filter Assembly on 

the top of the Tank

7

The purifier assembly is 

now ready

11

Tighten the Top Lid by pressing it 

down and rotating clockwise

Place the Top Lid on top of the 

Tank Assembly

+

Setting  up  your  KENT  Gold   

+

Maintaining your KENT Gold

Содержание Gold+

Страница 1: ...nufactured by Khasra No 93 Village Bantakhedi Tehsil Roorkee District Haridwar Uttarakhand 247 668 India KENT RO SYSTEMS LTD Instruction Handbook for Installation Operation and Maintenance System Test...

Страница 2: ...or any sickness or illness due to the consumption of drinking water from any water purifier supplied by KENT since KENT or its Authorised Service Provider does not have any control over the maintenanc...

Страница 3: ...xploded view of KENT Gold 4 7 Important instructions 5 8 Filtration process 5 9 Setting up your KENT Gold 6 10 Maintaining your KENT Gold 7 Part 1 Cleaning the UF Membrane 7 Part 2 Cleaning the water...

Страница 4: ...Operating Water Temperature 35 C Minimum Operating Water Temperature Filtration Capacity 0 31 litre per minute under standard testing conditions Usage The system should be used only with cold water 9...

Страница 5: ...ding on the quality of raw water 6 Replace the Sediment Filter every 3 months 7 Replace the Activated Carbon Filter every 6 months 1800 litres 8 Replace the UF Membrane every 12 months 9 At the time o...

Страница 6: ...STEMS LTD Gold Installation Manual 7 Fequency l The UF Membrane should be cleaned at least once in a month However if the water flowing from InnerTank to the Outer Tank reduces sharply Membrane can be...

Страница 7: ...lean both the Filters Pressure clean the Funnel under running tap water Part 2 Cleaning the Water Tanks 8 KENT RO SYSTEMS LTD 1 2 3 4 5 6 1 2 3 4 Frequency The Sediment Filter should be changed after...

Страница 8: ...f the Inner Tank Wipe dry all the plastic parts inside out with a clean cloth Re assemble the dry purifier 1 2 3 4 5 6 7 8 9 Frequency UF Membrane should be changed every year Press it down in collet...

Страница 9: ...fy dsUV k mlds vf k r lfoZl dsUnz dks ft Eesnkj ugha Bgjk k tk ldrk D ksafd dsUV k mlds vf k r lfoZl dsUnz dk okWVj I qfjQk j ds j kj kko vkSj bLrseky ij dksbZ fu a k ugha gSA 12 okjaVh vuqca k esa mR...

Страница 10: ...V xksYM dk foLr r n 4 7 egRoiw kZ funsZ k 5 8 fQYV s ku izf k 5 9 dsUV xksYM dk baLVkWys ku 6 10 dsUV xksYM dk j k j kko 7 Hkkx 1 w Q esEczsu dh lQkbZ 7 Hkkx 2 ikuh dh Vafd ksa dh lQkbZ 8 Hkkx 3 lsMhe...

Страница 11: ...Vj 1058 xSyu vf kdre vki W jf s Vx a ikuh dk rkieku 35 U wure vkWijsfVax ikuh dk rkieku 10 fQYV s ku kerk 0 31 yhVj izfr feuV LVSUMMZ VsfLVax ifjfLFkfr ksa ds rgr bLrseky BaMs ikuh ds fy C 95 F C 50 F...

Страница 12: ...062 fooj k dsUV xksYM Lis j fdV 20065 esEczsu dsUV xksYM 1 20063 fDVosfVM dkcZu 190xzke 1 20064 lsMhesaV fQYVj dsUV xksYM tksM h 14 bl flLVe ls igys k ckn esa fcuk fdlh ksX fMflaQsD ku ds vlqjf kr k v...

Страница 13: ...dks j ksaA Vd as lc as yh ij ijh Ddu yxk A as Ddu dks dl dj can djus ds fy mls kM h dh fn kk esa kqek saA vkidk I qfjQk j bLrseky ds fy rS kj gSA 1 2 3 10 12 5 6 4 8 9 7 11 l bart kj djsa l baLVkWys k...

Страница 14: ...d ckj vo lkQ djsaA mls mYVk dj ds j ksaA Ik kZIr ikuh Mkydj lsMhesaV oa dkcZu fQYVj dks vPNs ls kks aA fQYVj lsEcyh dks uy ds uhps rst kkj ls lkQ djsaA fQYVj gkmflx a dks kky s rs g q Quy ls vyx djA a...

Страница 15: ...j ikuh ysdj mls esEczsu esa batsDV djsaA vc u h esEczsu dks uhps dh vksj nckrs gq Hkhrjh Vadh esa fQV djsaA esEczsu dks ikuh dh fn kk ds foijhr Hkhrj Mkyrs le lko kkuh cjrsaA bls dkWysV esa uhps dh vk...

Отзывы: