18
OPERATION
(continued)
723,&
3266,%/(&$86(
62/87,21
Controls need to be adjusted.
See “Installation Instructions— How to Adjust the
Tem perature Controls” section on how to adjust your
controls.
See “Installation Instructions— How to Level Your
Refrigerator” section on how to properly level unit.
Check gaskets for proper seal. Clean, if necessary.
See
section on “Hints and Care— How to Clean Your Unit” for
instructions.
Refrigerator runs too
frequently (continued)
Door is not closing properly.
Check for internal obstructions that are keeping door from
closing properly (i.e. im properly closed drawers, ice
buckets, oversized or im properly stored containers or
foodstuffs, etc.).
ICE
Unit is leaking water
Plastic tubing was used to complete water
connection.
Sears recomm ends using copper tubing for installation.
Plastic is less durable and can cause leakage. Sears is
not responsible for property damage due to improper
installation or water connection.
Im proper water valve was installed.
See section on “Installation Instructions— How to Connect
the W ater Supply” for instructions.
Self-piercing and
3
/
16
”
saddle valves cause low water pressure and m ay clog the
line over time. Sears is not responsible for property
damage due to improper installation or water
connection.
Ice forms in inlet tube to ice
maker
W ater pressure is low.
W ater pressure m ust be between 20 to 100 pounds per
square inch to function properly. A m inimum pressure of 35
pounds per square inch is recommended for units with
water filters.
Freezer tem perature is too high.
See “Installation Instructions— How to Adjust the
Tem perature Controls” section on how to adjust your
controls.
Freezer is recom mended to be between 0 to 2°F
(-18 to –17°C).
W ater pressure is low.
W ater pressure m ust be between 20 to 100 pounds per
square inch to function properly. A m inimum pressure of 35
pounds per square inch is recommended for units with
water filters.
W ater flow is slower than
normal
Im proper water valve was installed.
See section on “Installation Instructions— How to Connect
the W ater Supply” for instructions
. Self-piercing and
3
/
16
”
saddle valves cause low water pressure and m ay clog the
line over time. Sears is not responsible for property
damage due to improper installation or water
connection.
Trouble Shooting