4
ENGLISH
pOWER FAILURE
When power to the freezer is restored after the occur-
rence of a power failure, the “Power Loss” LED will be
illuminated.
If the internal temperature of the freezer has risen to
a temperature greater than 23ºF (-5ºC), the “Hi Temp”
display indicator will also be illuminated and there will
be an audible beep every five seconds. Press the Alarm
Reset button to turn the audible alarm (beep) off.
If this condition persists, the “Duration” indicator will
also be illuminated and the display will show how many
hours (up to a period of 48) the internal temperature has
been above 23ºF (-5ºC). Food quality is considered to be
impaired at temperatures greater than 23ºF (-5ºC). It is left
to the user’s discretion to decide how to best manage the
contents within the freezer.
SYSTEM ERROR ALARMS
If “E7”, “E8”, or “E9” are shown on the display every half
second and the control panel beeps every five seconds,
call service repair to correct the problem. Press the Alarm
Reset button to turn the audible alarm (beep) off. Until
changes are made, freezer will continue to run.
Display Status
Function
Response
Cabinet
temperature
setting is
displayed
Normal operation None
Alternating “E’
and “7”, “8” or “9”
every half second
Operational error Contact service
technician.
Control panel
beeps every 5
seconds. “Door
Ajar” LED is lit.
Door Ajar
Close door. Press
Alarm Reset
to mute audible
alarm (beep).
Control panel
beeps every 5
seconds. “Hi
Temp” LED is lit.
Freezer
temperature too
high.
Contact service
technician. Press
Alarm Reset
to mute audible
alarm (beep).
“Power
Loss” LED is
illuminated.
A power failure
occurred.
Press
Alarm
Reset button.
Display off.
Power failure
Reconnect power
supply.
ALARM FUNCTION TABLE
Except during power loss, the alarm indicators illuminate
whenever there is an alarm status.
Figure 7