![Kenmore 795.78773.801 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/kenmore/795-78773-801/795-78773-801_service-manual_1955037023.webp)
- 23 -
Main PCB
WH
WH
R-Sensor
CON6
9
10
Refrigerator Sensor Error
Wiring diagram
Disconnect CON6 and measure
the value. Is resistance value
between pins 9 & 10 of CON6 as
below? (WH to WH)
Is the connection loose?
If the ER-rS appears, Replace
the main PCB. Otherwise,
explain to the customer!
Replace
R-sensor
No
pin10
pin9
Yes
6 ~ 300 k
Ω
Pin9 to pin10
Result
Test Point
Reconnect
Reconnect CON6 and Power ON
Power Off
Tip : To protection of MICOM
No
Yes
Is Er-FS displayed?
Yes