6-10. Error Code Summary
NO
Error Detection
Category
1
Normality
None
Normal operation of Display
2
Freezer Sensor
Error
Er
FS
Short or Disconnection
of Freezer Sensor
3
Refrigerator
Sensor Error
Er
rS
Short or Disconnection
of Refrigerator Sensor
Check each sensor and its
connector.
Error Generation Factors
Remark
WARNING:
When you check the Resistance values, be sure to turn off the power.
And wait for the voltage-discharge sufficiently.
Error Display
Freezer
Temperature
Ref.
Temperature
4
Defrosting
Sensor Error
Er
dS
Short or Disconnection
of Defrosting Sensor
5
Icing Sensor
Error
Er
IS
Short or Disconnection
of Icing Sensor
6
Poor Defrosting
Er
dH
Even though it is passed
1 hour since then Defrosting,
if Defrosting sensor is not
over 8°C, it is caused
Temperature Fuse
Disconnection, Heater
disconnection, DRAIN Jam,
Poor Relay for Heater
7
Abnormality of
BLDC FAN Motor
for Ice Making
Er
IF
It is caused when feedback
signal isn’t over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor
connection, DRIVE IC,
and TR
8
Abnormality of
BLDC FAN Motor
for Freezer
Er
FF
It is caused when feedback
signal isn’t over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor
connection, DRIVE IC,
and TR
9
Abnormality of
BLDC FAN Motor
for Mechanic
Room
Er
CF
It is caused when feedback
signal isn’t over 65 seconds
during BLDC FAN motor
operating
Poor BLDC Motor
connection, DRIVE IC,
and TR
10
Communication
Error
Er
CO
Communication Error
between Micom of Main
PWB and Display Micom
Poor Communication
connection,Poor TR of
Transmitter and Receiver