6-1. COMPRESSOR AND ELECTRIC COMPONENTS
1
2
3
4
5
2
5
5
3
5
1
4
3
YES
NO
YES
The range of resistance is between 1~50 ? (ok)
Open or short
YES
YES
NO
NO
Power Source.
No voltage.
(Rated voltage
Replace OLP.
Reconnect.
Refer to Page 23.
Did
compressor
Compressor
is OK
Replace the
compressor
Check connection
condition.
Advise customer that
power supply needs to be
checked by an electrician.
Supply
voltage rating
with ±10%.
Applied voltage isn't
in acceptable range.
(115V ±10%)
Remove PTC-Starter
from compressor and
measure voltage
between Terminal C of
compressor and
terminal 5 or 6 of PTC.
Check resistance of
two terminals in
PTC-Starter.
Check resistance of two
terminals in OLP.
Check the power supply
under load.
(Compressor attempting
to re-start after being off
for 5 minutes).
.
Check
resistance of
PTC-Starter.
Check OLP.
Check
starting state.
Check resistance
of motor
compressor.
Check the resistance
between M-C, S-C and
M-S in motor compressor.
Replace
compressor
Refer to Page 23.
Check
resistance of
motor
compressor.
6. TROUBLESHOOTING