- 28 -
8-1-11 TEST MODE
1. Test mode allows checking the PCB and the function of the product as well as determining the Defective part in case of an
error.
2. The test button is on the main PCB of the refrigerator (Test S/W).
3 While in the test mode, the ADJUST button will not operate.
4. After exiting the test mode, be sure to reset by unplugging and plugging in the appliance,
5. If an error, such as a sensor failure is detected while in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated.
MODE Key Control Operation Remarks
1) Continuous operation of the
Push the test COMP, Freezer FAN
button once and Cooling FAN. *The maximum
TEST 1 2) DEFROSTING HEATER OFF time for TEST 1
3) ALL DISPLAY ON is 5 min.
4) LAMP RELAY ON/OFF
OPERATED BY DOOR SWITCH
1) COMP OFF Ref. Temp. Display
Push the test 2) Freezer FAN and Cooling
button once while FAN OFF
in TEST MODE 1 3) Defrosting Heater ON
TEST 4) 1, 3, 5 LED ON
Operate max 1 Hr
Push the test button Reset to the default settings
Once while in TEST (Compressor will delay 7
RESET MODE 2 minutes for Power ON)
:ON :OFF
R1
R3
R5
Содержание 795.75312.900
Страница 29: ...8 2 PCB FUNCTION 29 Con 1 Con 3 Con 2 Con 8 Con 2 Con 5 Con 6 Con 7 ...
Страница 41: ...July 2009 ...