- 18 -
0
Ω
OFF
Other
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-2)
Result
SVC Action
7-2 Refrigerator Sensor Error (Er rS)
No
1
2
Checking flow
Check for a loose connection.
Check the White to White.
Result & SVC Action
<Temperature table-2>
(1) To (2)
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38.5 ~ 36.5
㏀
30.5 ~ 29.5
㏀
24.5 ~ 23.5
㏀
20 ~ 19
㏀
16 ~15.5
㏀
※
The sensor is determined by
the temperature.
For example, 30
㏀
indicates 32°F.
<CON4>