8-1-10 TEST Mode
1. The Test mode allows checking the PCB and the function of the product as well as finding out the defective part in case of
an error.
2. The test mode is operated by pressing two buttons at Display panel.
3. While in the test mode, the function control button is not recognized, but the recognition tone (beep~) sounds.
4. After exiting the test mode, be sure to reset by unplugging and then plugging in the appliance.
5. If an error, such as a sensor failure, is detected in the test mode, the test mode is cleared and the error code is
displayed.
6. While an error code is displayed, the test mode will not be activated.
NOTE
:
LED CHECK MODE: When the ADJUST REFRIGERATOR TEMP KEY & ADJUST FREEZER TEMP Keys are pressed at the
same time and hold for 1 second or longer, every LED on the display turns on at the same time. when the button are
relesed, the previous mode is restored.
* Freezer Fan RPM Variable Check:
In case the freezer fan is in operation when the COLD KEY in Refrigerator and Freezer Temp. Control are pressed for
more than one second at the same time freezer fan RPM changes. (for example if high speed, to normal speed or if
normal speed, to high speed for 30 seconds)
After 30 seconds, it turns to its original RPM.
* Demonstration MODE:
1. When the ULTRA ICE key and ADJUST key of refrigerator temperature control are pressed for
more than 3 seconds at the same time, temperature’s it converts to demonstration mode.
2. In this status, each LED is rotated with 1 second interval.
3. In this status, all Loads are off (Compressor / Fan / Damper / Heater)
(Even is Demonstration Mode, the refrigerator Lamp automatic off function warks normally and can be demonstrated)
4. It reset if you do again as clause.
- 24 -
MODE
MANIPULATION
CONTENTS
REMARKS
TEST1
TEST2
Reset
Push ULTRA ICE &
ADJUST FREEZER
TEMP Keys at the
same time over 3
seconds.
Push ULTRA ICE &
ADJUST FREEZER
TEMP Keys at the
same time over 3 seconds
in TEST MODE 1
Push ULTRA ICE &
ADJUST FREEZER
TEMP Keys at the
time over 3 seconds. in
TEST MODE 2
1. Continuous operation of the
COMPRESSOR
2. Continuous operation of the freezer fan
3. STEPPING DAMPER OPEN
4. Defrosting Heater OFF
5. Every DISPLAY LED ON
1. COMP OFF
2. Freezer FAN OFF
3. STEPPING DAMPER CLOSE
4. Defrosting heater ON
5. DISPLAY LED 1, 3, 5, 7 ON
Reset to the previously setting before
TEST MODE
Reset if the
temperature of the
Defrosting sensor is
46
°
F (8
°
C) or more.
The compressor will
Start after a 7-minute
delay.
Содержание 795.65002.402
Страница 10: ...GY GRIS GRAY 10 5 CIRCUIT DIAGRAM ...
Страница 36: ...8 5 MAIN PWB ASSEMBLY AND PARTS LIST 8 5 1 Main PWB Assembly 36 ...
Страница 37: ...8 5 2 Replacement Parts List 37 ...
Страница 38: ...8 5 3 PWB Assembly Display And Parts List 38 ...
Страница 39: ...8 6 PWB DIAGRAM 8 6 1 PWB Main Assembly 39 G5S 1A RY5 ...
Страница 40: ... 40 ...
Страница 43: ...125A 131A 149A 136C 282X EV FREEZER PARTS CAUTION Use the part number to order part not the position number 43 ...
Страница 52: ......