![Kenmore 795.583*.410 Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/kenmore/795-583-410/795-583-410_service-manual_1954945070.webp)
TEST MODE 1
Voltage [V]
CON3
5
nd
pin ~ 6
th
pin
0V
Defrost Heater Error (F dH)
1
Replace the
Door gasket
Check the Door gasket .
Is door gasket damaged?
Yes
No
2
Check the Defrost control part.
(1) Is Fuse-M resistance 0 Ω?
(2) Is Defrost Heater resistance
48~54Ω?
No
Yes
Change
Fuse-M
4
Check the Heater Voltage.
Is voltage 112~116V?
Yes
3
Check the Defrost control part.
Is Defrost Sensor resistance
22kΩ
↑
or OFF?
OFF
22kΩ
↑
Replace
product
Input Test 2 Mode
(Push the button 2 times)
Replace
Main PCB
NO
TEST MODE 2
Voltage [V]
CON3
5
nd
pin ~ 6
th
pin
112V ~ 116V
5
Check the Heater Voltage.
Is voltage 0V?
Yes
Input Test 1 Mode
(Push the button 1 times)
Replace
Main PCB
No
6
Explain to customer
CON3
CON3
70