background image

Содержание 79097512100

Страница 1: ...r 0 020 copper The minimum clearance is 0 for the rear of the range Follow all dimension requirements provided above to prevent property damage potential fire hazard and incorrect countertop and cabinet cuts Avoid locating cabinet storage space above the surface units to eliminate the possibility of cabinets catching on fire or personal burns from reaching for the cabinets over the heated units If...

Страница 2: ...ds or from the range itself If range is ever moved to a different location the anti tip brackets must also be moved and installed with the range Instructions are provided for installation in wood or cement floor When fastening to floor be sure that screws do not penetrate electrical wiring or plumbing A Locate the Bracket Using the Template Locate the bracket position right or left side by placing...

Страница 3: ...level by placing a spirit level on the oven rack Take 2 readings with the spirit level placed diagonally A take a reading in one direction and then in the other direction Level the range if necessary by adjusting the B leveling legs C Serial Plate Information The serial plate is located as shown See the serial plate for the following information Model tot and serial number of range Kilowatt rating...

Страница 4: ...cm dia hole as shown on figure 9 If a larger hole is required punch out the knockout Risk of fire or electrical shock exists if an incorrect size range cord kit is used the Installation instructions are not followed or the strain relief bracket is discarded For mobile homes new installation or recreational vehicles use only a power cord kit design for a range at 125V 250V 50A recommended minimum 4...

Страница 5: ...to Range Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord see Figure 9 1 Remove the screws from the access plate at the lower right end of the rear cover to expose range terminal connection block 2 Remove the grounding strap from the terminal block and from the appliance frame 3 Using the nuts supplied with the litera...

Страница 6: ...lectrical System Example Junction Box Where local codes DO NOT permit connecting the appilance grounding conductor to the neutral white wire or if connecting to 4 wire electrlca system see Figure 11 1 Be sure that no power is supplied on the cable from residence 2 Follow instructions on previous page for Four Conductor Wire Connection to Range Fig 9 3 In the circuit breaker fuse box or junction bo...

Страница 7: ...s de 4 de material retardante con una hoja de acero de no menos MSG No 28 0 015 de acero inoxidable 0 024 de aJuminio o 0 020 de cobre 0 es el espacio minima para la parte trasera de la estufa iga todos los requerimientos de medidas antes proporcionados para evitar daBos a la propiedad peiigro de incendios potenciales o superficies y cortes de gabinetes que sean incorrectos Para ellmlnar el rlesga...

Страница 8: ...con la cocina Las instrucciones provistas sirven para instalaci6n en suelo de madera o concreto AI fijar los tornillos al suelot asecju rase que no atraviesen la instalaci6n el_ctrica o de fonta nerfa B Perforaci6n de agujeros pilato y manfura de sujeci6n Perfore un agujero piloto de 1 8 ell el lugar en el qua se vayan a instalar los tornillos Si la montura se va a instalar a en la pared_ practiqu...

Страница 9: ...oque un nivel en las parrillas interior del horno Tome m_nimo 2 lecturas con el nivel coloque el nivel en diagonal para que la cocina este nivelada de atr6s hacia adelante si es necesario ajuste las paras niveladoras o Placa de Identificaci6n Esta plata de identificaci6n est6 Iocalizada sobre el marco y se puede ver cuando la cjaveta est6 abierta Consulte la piaca de identificaci6n para obtener la...

Страница 10: ...l tama_o minimo del cable a utilizarse el listado general de la UL c6dicjo local puede diferenciar NOTA La cocina corrediza el6ctrica viene de fabrica con un acjujero de di6metro 1 1 8 2 9 cm come se muestra en la flcjura 4 Si un acjujero mas largo est6 necesario retire la arandela de la pre cortada El riesgo de fuego o de choque el_ctrico puede aparecer si usa el tamafio de cable incorrecto si la...

Страница 11: ...minal y vuelva al colocar los tornillos Terminal plata Alambre rojo Bloque terminal Alambre Negro Conexi6n del cable de cuatro conductores a la cocina 1 Retire los tornillos de la parte baja de la cubierta del cable trasero cubierta de acceso para tener acceso al bloque de conexi6n del borne terminal 2 Retire la correa de la base del bloque terminal y del armaz6n del electrodom6stico Retencja el t...

Страница 12: ...Figura 5 _ _ Alambres _ negros j de i _ Allambre _ Condu_ icd e uni6n listado UL listado CSA Donde los c6digos locales NO permitan conectar el conductor de puesta a tierra del electrodom6stico al neutral blanco o si est6 conectado con un sistema a 4 alambres vea figura 6 1 Desconecte el suministro el6ctrico 2 Sicja las instrucciones en la p6cjina anterior para la conexi6n dei aiambre de cuatro con...

Отзывы: