7-23
PROBLEM - E:
Unit does not heat up even if display counts down when
START key is touched for “HIGH
POWER” cooking.
Check: 1. PRIMARY AND SECONDARY INTERLOCK SWITCHES
2. THERMOSTAT
1
2
Runs
Runs
Runs
Contact
OK
Resistance
incorrect
Check the continuity of
H.V.C. (see page 7-16)
Normal H.V.T.
Resistance
incorrect
Normal H.V.C.
Abnormal
Replace H.V.D.
Normal
Magnetron
Replace
Magnetron
Normal
Normal
H.V.D.
Check the
continuity of H.V.D.
(see page 7-16)
Replace H.V.C.
Normal
resistance
Replace H.V.T.
Normal
resistance
NO
continuity
Replace
circuit board
Normal
circuit board
Poor contact
Replace
circuit board
Normal
circuit board
Contact OK
Normal
contact
Correct
seating
Check contact of
connector S1
Runs
Runs
Runs
Runs
Check the contact of
relay 2(see page 7-18)
Measure resistance of
H.V.Transformer
(see page 7-15)
Содержание 767. 8513000
Страница 7: ...CONTROL PANEL 4 1 OPERATING INSTRUCTIONS For Model 85130 85138 85139 For Model 85140 ...
Страница 9: ...5 1 A B C SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Страница 10: ...MATRIX CIRCUIT FOR TOUCH KEY BOARD For Model 85130 85138 85139 For Model 85140 5 2 ...
Страница 38: ...8 2 CONTROLLER PARTS EV 24781M 23572A 26638A 24810P 268711 WTP018 07 ...
Страница 40: ...8 4 466001 43501A 43500A 466003 466001 44510A WSZ084 LATCH BOARD PARTS EV ...
Страница 43: ...8 7 INSTALLATION PARTS 65862D 63300M 63861A 65862B EV ...
Страница 44: ...8 16 SCHEMATIC DIAGRAM OF P C B ...
Страница 45: ...8 17 PRINTED CIRCUIT BOARD ...
Страница 46: ...P NO 3828W5S1807 Printed in Korea ...