Kenmore 625.385700 Скачать руководство пользователя страница 16

Содержание 625.385700

Страница 1: ... 8pm CST For repair or replacement parts call this toll free num ber 1 800 366 7278 See back cover for other Sears service numbers www KenmoreWater com SAVE THIS MANUAL Reverse Osmosis Drinking Water System _i Warranty _i How To Install _i How It Works _i Care Of _i Repair Parts System tested and certified by NSF International to NSF ANSl Standard 58 for the reduction of the claims specified on th...

Страница 2: ...make safe drinking water from non potable water sources Do not use the system on microbiologically unsafe wa ter or water of unknown quality without adequate disinfection before or after the system This system is certified for cyst reduction and may be used on disinfected water that may contain filterable cysts Check with your local public works department for plumbing and sanitation codes You mus...

Страница 3: ...s will look and taste better too Having high quality RO product wa ter at your fingertips eliminates the need to buy bottled water The storage tank holds over 2 gallons of RO product water for your needs BEFORE YOU BEGIN TO INSTALL THE RO SYSTEM FOR OPTIMUM PERFORMANCE YOUR KEN MORE REVERSE OSMOSIS SYSTEM SHOULD BE INSTALLED ON SOFTENED WATER CAUTION A refrigerator icemaker may not operate properl...

Страница 4: ...luded feed supply fitting or install pipe fittings for tubing connection as typical ly shown on page 5 Drain Point A suitable drain point is needed for re ject water from the RO membrane A floor drain laundry tub standpipe sump etc is preferred as shown in the remote locations drawing page 19 A sink p trap drain adaptor is included to install where codes permit as an optional drain point page 6 RO...

Страница 5: ...ompound or Teflon tape on cold water faucet stud threads and on the mate threads of the water supply fitting that connect to the cold water pipe B OPTIONAL PIPE FITTINGS compression type shown Note Be sure to turn off the water supply and open a low faucet to drain the pipe Complying with plumbing codes install a fitting on the kitchen cold water pipe to adapt 1 4 D tubing A typical connection is ...

Страница 6: ...ed end of the adapter Do not cut too short so the adapter will make a leak tight seal with the connecting fitting 4 Assemble the p trap to the drain adapter and oth er drain pipe fittings as required check codes to complete the drain run 5 Tighten all connections but do not overtighten and break plastic fittings P trap Figure 4 ferrule 0 I_yrain adapter black J __u 45_ 4_ _ cut if _ t X i needed 1...

Страница 7: ...bing adaptor 5 Lower faucet into place on the countertop on the underside of the countertop or sink slide the slotted washer into place and tighten plastic nut Tighten the nut so the faucet cannot move but do not over tighten UltraFilter 150 faucet spout H hole in sink or b__i_ bers slotted washer _ _ washer _ _ hex nut _ _ 1 4 red tubing from RO drain connect to 1 4 barb on faucet 3 8 blue tubing...

Страница 8: ...ached to the faucet using the 1 4 x 1 4 quick connector 6 Remove the spout from the top of the faucet by pulling it straight upward 7 Remove the faucet knob by pinching the two lock ing tabs inward and then pulling upward on the knob while the tabs are pinched inward See Figure 8 8 Push the coin cell battery into the battery holder be hind the circuit board NOTE the side of the bat tery goes again...

Страница 9: ...t correctly To change the battery pull the spout and bezel from the faucet base The bezel will stay on the spout Pinch the two tabs under bezel on faucet with one hand and with the other pull up on the knob Change battery Assemble the the knob and spout and bezel back onto the faucet base Figure 8 STEP 4 INSTALL RO ASSEMBLY Hang the assembly on the included hanger washers or lay on the cabinet flo...

Страница 10: ...age 16 3 Move the storage tank into place next to the RO as sembly You can stand the tank upright or lay it on side Apply no more than two wraps of Teflon tape to the threads on the nipple at the top of the tank Hand tighten the other included tubing adapter fit ting with the yellow collet onto the tank nipple then wrench 1 4 turn only BE CAREFUL NOT TO CROSS THREAD 4 Run the 3 8 yellow tubing to ...

Страница 11: ...left 10 Allow water to circulate through the R system until you smell the bleach odor at the faucet Then close the faucet and allow the R to stand idle for 20 minutes 11 After the 20 minutes open the R faucet and run water until the bleach odor is gone 12 Turn off the water supply to the R 13 Be sure your hands are clean Then repeat steps 1 5 and 7 only replace all cartridges Important Refer to Fi...

Страница 12: ...lter is an activated carbon type filter Any remaining tastes and odors are removed from the product water Taste free odor free clean high quality drinking water is available for use FAUCET The sink or countertop faucet has a hand operated knob to access drinking water An air gap is built into the faucet drain water connection to comply with plumbing codes FAUCET ELECTRONICS UltraFilter 350 The RO ...

Страница 13: ...tical for effective removal of total dissolved solids The monitor faucet feature provides continuous analysis of the systems performance For systems not equipped with the monitor faucet function it is highly recommended that you have your water tested at least every 6 months to verify your system is performing properly Test kits are available by calling 1 800 826 8553 ext 47 or check the water tes...

Страница 14: ...rn off the water supply and open the RO faucet to relieve pressure 2 Remove turn to the left both sumps from the filter heads Be careful the sumps are full of water 3 Remove and discard the inner cartridges in a prop er manner Flush the insides of the sumps with fresh water Do not lose the large o ring seals 4 Insert new cartridges with o ring seals towards the top and with lubricated o rings in p...

Страница 15: ...faucet to relieve pressure 2 Remove turn to the left the sump from the filter head Be careful the sump is full of water 3 Remove and discard the RO cartridge in a proper manner Flush the insides of the sump with fresh wa ter Do not lose the large o ring seals Note Sanitizing is recommended after servicing in ner parts of the system see page 11 4 Insert new RO cartridges with o ring seals to wards ...

Страница 16: ...15 1 With a small screwdriver remove the collet and o ring from the fitting Be careful not to scratch the in ternal walls of the collet port 2 Be sure the port is clean then lubricate and insert the o ring seal to the bottom of the port 3 Push the collet inward until it locks in place collet depress to remove tubing tubi_ _ Replacing collet and o ring seal Push o ring seal into bottom of port then...

Страница 17: ... is needed Correct this condition before doing maintenance on the RO system Replace the prefilter post filter and RO membrane cartridges Replace the post filter cartridge If taste and odor persists re place the prefilter cartridge and RO membrane cartridge Use sanitizing procedures Replace the post filter cartridge System makes product Increase water pressure precondition the water etc as needed w...

Страница 18: ...tem conforms to NSF ANSI 58 for the specific performance claims as verified and sub stantiated by test data Feed water supply at 50 psi 77 F and 750 TDS Quality water production amount of waste water and percent rejection all vary with changes in pressure temperature and total dissolved solids 12 Efficiency rating means the percentage of the influent water to the system that is available to the us...

Страница 19: ...the faucet airgap and p trap drain This type of drain is the preferred over the p trap drain adapter Check your local codes Always be sure to provide an air gap between the end of the hose and the drain point REMOTE RO INSTALLATION storage tank not shown water faucet OPTIONAL DRAIN POINTS FOR REJECT WATER STANDPIPE 1 4 red LAUNDRY TUB airgap I FLOOR DRAIN Note Tubing colors as supplied with RO sys...

Страница 20: ...se Osmosis Drinking Water System Model Nos 625 385700 625 385720 6 7 b 19_i C 0 _J 14 13 15 22 11 12 21 Manifold Housing PUSH IN FITTINGS 1 4 _21 3 8 o ring seal eollet 20 Problems Questions Call 1 800 426 9345 Kenmore Water Line 10 1 4 Tubing ...

Страница 21: ...aucet Model 625 385700 7266584 Faucet Model 625 385720 20 7234333 Cover 21 7209566 Push in Fitting Kit 1 4 A 7209574 Push in Fitting Kit 3 8 O 22 7255101 Manifold incl key nos 5 thru 9 7266568 Owner s Manual Faucet Battery Model 625 385720 only purchase locally DuraceII DL2032 or Eveready ECR2032 Optional Accessories and Tubing 7161823 Tubing 1 4 x20 white _ 7161784 Tubing 1 4 x 100 white _ 715728...

Страница 22: ... NOTES 22 Problems Questions Call 1 800 426 9345 Kenmore Water Line ...

Страница 23: ... NOTES 23 Problems Questions Call 1 800 426 9345 Kenmore Water Line ...

Страница 24: ... to do _t yoorse_ For Sears professional instaflation of home appliances and items like garage door openers and water heaters HHHHHH 1 800 4 MY HOME _ 1_8004694663 co oo_ mo 0ay or _ g _ _and c 0 oa_ www sea_ som www sears ca Our Home For repair of carry in items tike vacuums lawn equipment and electronics call or go omline for the location of your nearest Sears Parts Repair Center 1 8o0488 t ca o...

Отзывы: