POWER SUPPLY CORD - The dryer is equipped with a 120
volt 3-wire power cord.

NOTE: Do not under

any circumstances

remove grounding

prong from plug.

GAS Dryer

CIRCUIT - Individual 15 amp. branch circuit fused with a 15
amp. maximum time delay fuse or circuit breaker.

POWER SUPPLY - 3 wire, 120 volt single phase, 60 Hz,
Alternating Current.

O U T L E T

RECEPTACLE

(COPPER)

3 WIRE GROUNDED NEUTRAL
120-240 VOLT 60 CYCLE
MAIN FUSE BOX

30 AMP DELAYED ACTION
F U S E S
OR CIRCUIT BREAKER
NEUTRAL WIRE

NEMA 10-30R (COPPER)

SUBJECT TO LOCAL
 REGULATIONS

POWER SUPPLY

GROUNDING PRONG

EXHAUST SYSTEM REQUIREMENTS

Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible
metal duct and approved vent hood which has a swing-out
damper(s) that open when the dryer is in operation. When the
dryer stops, the dampers automatically close to prevent drafts
and the entrance of insects and rodents. To avoid restricting
the outlet, maintain a minimum of 12 inches (30.5 cm) clearance
between the vent hood and the ground or any other obstruction.

 The following are specific requirements

for proper and safe operation of your dryer. Failure to
follow these instructions can create excessive drying
times and fire hazards.

  Do not use plastic flexible duct to exhaust the dryer.

Excessive lint can build up inside exhaust system and create
a fire hazard and restrict air flow. Restricted air flow will increase
dryer times. If your present system is made up of plastic duct
or metal foil duct, replace it with a rigid or flexible metal duct.
Ensure the present duct is free of any lint prior to installing
dryer duct.

 If the dryer is not exhausted outdoors, some fine lint will

be expelled into the laundry area. An accumulation of lint in
any area of the building can create a health and fire hazard.
The dryer exhaust system MUST be exhausted to the
outside of the building!

 Do not allow combustible materials (for example: clothing,

draperies/curtains, paper) to come in contact with exhaust
system. The dryer MUST NOT be exhausted into a chimney,
a wall, a ceiling, or any concealed space of a building which
can accumulate lint, resulting in a fire hazard.

 Exceeding the length of duct pipe or number of elbows

allowed in the "MAXIMUM LENGTH" charts can cause an
accumulation of lint in the exhaust system.  Plugging the
system could create a fire hazard, as well as increase drying
times.

 Do not screen the exhaust ends of the vent system, nor

use any screws or rivets to assemble the exhaust system.
Lint can become caught in the screen, on the screws or rivets,
clogging the duct work and creating a fire hazard as well as
increasing drying times. Use an approved vent hood to terminate
the duct outdoors, and seal all joints with duct tape. All male
duct pipe fittings MUST be installed downstream with the flow
of air.

PRE-INSTALLATION REQUIREMENTS

Tools and Materials Required for Installation:
 1.  Phillips head screwdriver.
 2.  Channel-lock adjustable pliers.
 3.  Carpenter's level.
 4.  Flat or straight blade screwdriver.
 5.  Duct tape.
 6.  Rigid or flexible metal 4 inch (10.2 cm) duct.
 7.  Vent hood.
 8.  Pipe thread sealer (Gas).
 9.  Plastic knife.

ELECTRICAL REQUIREMENTS

ELECTRIC Dryer

CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp.
minimum time delay fuses or circuit breakers.

POWER SUPPLY - 3 wire, 240 volt, single phase, 60 Hz,
Alternating Current.

POWER SUPPLY CORD KIT - The dryer MUST employ a 3-
conductor power supply cord NEMA 10-30 type SRDT rated
at 240 volt AC minimum, 30 amp., with 3 open end spade lug
connectors with upturned ends or closed loop connectors and
marked for use with clothes dryers, OR a 4-conductor power
supply cord NEMA 14-30 type SRDT or ST (as required) rated
at 240 volt AC minimum, 30 amp., with 4 open end spade lug
connectors with upturned ends or closed loop connectors and
marked for use with clothes dryers. See ELECTRICAL
CONNECTIONS FOR A 4-WIRE SYSTEM.

OUTLET RECEPTACLE - NEMA 10-30R  or 14-30R receptacle
to be located so the power supply cord is accessible when
the dryer is in the installed position.

Typical 3-wire installation

  Explosion hazard.  Do not install the dryer

where gasoline or other flammables are kept or stored. If the
dryer is installed in a garage, it must be a minimum of 18
inches

Содержание 417.64182300

Страница 1: ...at nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn th...

Страница 2: ...NECTIONS FOR 3 WIRE SYSTEM ELECTRIC Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L listed strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L listed 30 amp power cord NEMA 10 30 Type SRDT through the strain...

Страница 3: ...per and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply For a permanently connected dryer 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding con duc...

Страница 4: ... the door 180 and reinstall the door hinges to the dryer front panel with the four screws 4 Install the four hinge hole plugs in the open screw holes on the right side of the door opening UNPACKING 1 Using the four shipping carton corner posts two on each side carefully lay the dryer on its left side and remove foam shipping base To prevent damage do not use the control panel or coin meter housing...

Страница 5: ... minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length of the door is acceptable MINIMUM INSTALLATION CLEARANCES Inches FRONT SIDES REAR TOP Alcove 0 0 cm 0 0 cm 0 0 cm 15 38 1 cm Closet 1 2 54 cm 0 0 ...

Страница 6: ... condensation and faster accumu lation of lint Compression or crimping of the exhaust system will cause an increase in vent restriction The exhaust system should be inspected and cleaned a minimum of every 6 months with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation EXHAUSTDIRECTION All dryers shipped from the factory a...

Страница 7: ...usted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase drying times Do not screen the exhaust ends of the vent sy...

Страница 8: ...ments 2 Exhaust System Requirements 2 3 Gas Supply Requirements 3 Location of Your Dryer 4 Rough In Dimensions 5 Unpacking 5 Reversing Door Swing 5 Electrical Installation 6 Grounding Requirements 6 Electrical Connections 3 wire 7 Electrical Connections 4 wire 7 Installation 8 Replacement Parts 8 Lint Blade Retaining Pin Location 8 Printed in U S A P N 134313400 0309 Installation Instructions Gas ...

Страница 9: ......

Страница 10: ... part order give the complete model number shown on the serial plate located on the inside of the dryer door All repair parts listed are available for immediate purchase or special order when you visit your nearest Sears Service Cen ter To order parts by phone call the toll free parts number listed to the left When requesting service or ordering parts always provide the following information Produ...

Страница 11: ...10 03 2 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number CABINET DRUM ...

Страница 12: ...t hinge rear top panel mtg 21 134122572 Drum dryer painted service kit 24 131963900 Glide drum 25 5303015671 Screw hex washer head 8 18 x 0 375 cup point 29 131382300 Screw quadrex head 10 14 x 1 00 vane mtg special 30 5303201200 Vane straight 32 131777700 Shaft drum support ballhitch 32 5303307893 Lubricant high temp 33 3204267 Thermostat safety 34 131243700 Screw pan head 8 18AB x 0 375 cr sq dr...

Страница 13: ...10 03 4 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number FRONT PANEL LINT FILTER ...

Страница 14: ... Adhesive high temp 21 134134700 Seal felt lower 22 131845902 Panel front white with lamp hole 22 131870700 Plug light hole 22 131474700 Insulation 25 131658800 Door Catch 26 131843100 Switch door w o drum light 27 131450300 Trap lint blade assy 28 5303281074 Clip guide 3 41 131627500 Hinge door 42 131209600 Screw flat head 8 18AB x 0 44 cr sq drive 44 131129900 Gasket door seal 46 131644700 Handl...

Страница 15: ...10 03 6 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number CONTROLS TOP PANEL P16C0217 24 66 4 7 29 17 10 65 15 23 53 58 57 59 47 48 61 61 ...

Страница 16: ...134028500 Wiring Harness controls 134310100 Wiring Harness main 24 131970200 Button push start white 29 131666969 Console frame w trim tape 47 134274000 Meter Case assy 47 5304435395 Mounting Hardware meter case security 48 134028000 Gasket meter housing 53 134086822 Panel dryer top white coin op 57 3205253 Screw pan head 6 20B X 0 375 58 131863800 Retainer button plug 59 131863700 Plug button 61 ...

Страница 17: ...10 03 8 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number MOTOR 47 52 10 34 15 4 28 27 11 20 23 34 7 46 25 P16M0027 22 52 48 51 ...

Страница 18: ...11 131749800 Spacer idler 15 131298300 Thermostat temp control 20 131017900 Screw hex head 1 4 20T x 1 25 spacer mtg thread cutting 22 131601000 Spring idler arm 23 131863002 Idler Arm Assy w pulley clip 25 134163400 Belt dryer 27 134242400 Clamp motor mtg 28 131560100 Motor main drive w pulley 34 131243700 Screw pan head 8 18AB x 0 375 cr sq drive 46 134203400 Bracket motor mtg 47 131633300 Seal ...

Страница 19: ...10 03 10 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number WIRING DIAGRAM ...

Страница 20: ......

Отзывы: