Kenmore 417.64182300 Скачать руководство пользователя страница 1

8

INSTALLATION

1. GAS CONNECTION 

(Gas dryers only)

a. Remove the shipping cap from gas pipe at the rear of

the dryer.

NOTE: DO NOT connect the dryer to L.P. gas service without

converting the gas valve. An L.P. conversion kit must
be installed by a qualified gas technician.

b. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved

pipe from gas supply line to the 3/8 inch (0.96 cm) pipe
located on the back of the dryer. Use a 1/2 inch to 3/8
inch (1.27 cm to 0.96 cm) reducer for a connection.
Apply an approved thread sealer that is resistant to the
corrosive action of liquefied gases on all pipe
connections.

c. Open the shutoff valve in the gas supply line.

d. Test all connections by brushing on a soapy water

solution. NEVER TEST FOR GAS LEAKS WITH AN
OPEN FLAME.

2. Connect the exhaust duct to outside exhaust system. Use

duct tape to seal all joints.

3. With the dryer in its final position, adjust one or more of

the legs until the dryer is resting solid on all four legs.
Place a level on top of the dryer. THE DRYER MUST BE
LEVEL AND RESTING SOLID ON ALL FOUR LEGS.

4. Plug the power cord into a grounded outlet. NOTE: Check

to ensure the power is off at circuit breaker/fuse box before
plugging the power cord into the outlet.

5. Turn on the power at the circuit breaker/fuse box.

 Before operating the dryer, make sure the dryer

area is clear and free from combustible materials, gasoline,
and other flammable vapors. Also see that nothing (such as
boxes, clothing, etc.) obstructs the flow of combustion and
ventilation air.

6. Run the dryer through a cycle check for proper operation.

NOTE: On gas dryers, before the burner will light, it is
necessary for the gas line to be bled of air. If the burner
does not light within 45 seconds the first time the dryer is
turned on, the safety switch will shut the burner off. If this
happens, turn the timer to "OFF" and wait 5 minutes before
making another attempt to light.

7. Place these instructions in a location near the dryer for

future reference.

NOTE: A wiring diagram is located inside the dryer.

REPLACEMENT PARTS

If replacement parts are needed for your dryer, contact the
source where you purchased your dryer, or call Sears Parts
and Service Toll Free Number 1-800-4-MY-HOME (1-800-469-
4663).

 Label all wires prior to disconnection when

servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.

 Destroy the carton and plastic bags after the

dryer is unpacked. Children might use them for play. Cartons
covered with rugs, bedspreads, or plastic sheets can become
airtight chambers causing suffocation. Place all materials in
a garbage container or make materials inaccessible to
children.

 The instructions in this manual and all other

literature included with this dryer are not meant to cover every
possible condition and situation that may occur. Good safe
practice and caution MUST be applied when installing,
operating and maintaining any appliance.

Lint Blade Retaining Pin Location and Orientation

Install the pins after the lint blade is installed.

Содержание 417.64182300

Страница 1: ...at nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happens turn th...

Страница 2: ...NECTIONS FOR 3 WIRE SYSTEM ELECTRIC Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L listed strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L listed 30 amp power cord NEMA 10 30 Type SRDT through the strain...

Страница 3: ...per and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired power cord with a copper wired receptacle NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply For a permanently connected dryer 1 The dryer MUST be connected to a grounded metal permanent wiring system or an equipment grounding con duc...

Страница 4: ... the door 180 and reinstall the door hinges to the dryer front panel with the four screws 4 Install the four hinge hole plugs in the open screw holes on the right side of the door opening UNPACKING 1 Using the four shipping carton corner posts two on each side carefully lay the dryer on its left side and remove foam shipping base To prevent damage do not use the control panel or coin meter housing...

Страница 5: ... minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length of the door is acceptable MINIMUM INSTALLATION CLEARANCES Inches FRONT SIDES REAR TOP Alcove 0 0 cm 0 0 cm 0 0 cm 15 38 1 cm Closet 1 2 54 cm 0 0 ...

Страница 6: ... condensation and faster accumu lation of lint Compression or crimping of the exhaust system will cause an increase in vent restriction The exhaust system should be inspected and cleaned a minimum of every 6 months with normal usage The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation EXHAUSTDIRECTION All dryers shipped from the factory a...

Страница 7: ...usted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase drying times Do not screen the exhaust ends of the vent sy...

Страница 8: ...ments 2 Exhaust System Requirements 2 3 Gas Supply Requirements 3 Location of Your Dryer 4 Rough In Dimensions 5 Unpacking 5 Reversing Door Swing 5 Electrical Installation 6 Grounding Requirements 6 Electrical Connections 3 wire 7 Electrical Connections 4 wire 7 Installation 8 Replacement Parts 8 Lint Blade Retaining Pin Location 8 Printed in U S A P N 134313400 0309 Installation Instructions Gas ...

Страница 9: ......

Страница 10: ... part order give the complete model number shown on the serial plate located on the inside of the dryer door All repair parts listed are available for immediate purchase or special order when you visit your nearest Sears Service Cen ter To order parts by phone call the toll free parts number listed to the left When requesting service or ordering parts always provide the following information Produ...

Страница 11: ...10 03 2 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number CABINET DRUM ...

Страница 12: ...t hinge rear top panel mtg 21 134122572 Drum dryer painted service kit 24 131963900 Glide drum 25 5303015671 Screw hex washer head 8 18 x 0 375 cup point 29 131382300 Screw quadrex head 10 14 x 1 00 vane mtg special 30 5303201200 Vane straight 32 131777700 Shaft drum support ballhitch 32 5303307893 Lubricant high temp 33 3204267 Thermostat safety 34 131243700 Screw pan head 8 18AB x 0 375 cr sq dr...

Страница 13: ...10 03 4 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number FRONT PANEL LINT FILTER ...

Страница 14: ... Adhesive high temp 21 134134700 Seal felt lower 22 131845902 Panel front white with lamp hole 22 131870700 Plug light hole 22 131474700 Insulation 25 131658800 Door Catch 26 131843100 Switch door w o drum light 27 131450300 Trap lint blade assy 28 5303281074 Clip guide 3 41 131627500 Hinge door 42 131209600 Screw flat head 8 18AB x 0 44 cr sq drive 44 131129900 Gasket door seal 46 131644700 Handl...

Страница 15: ...10 03 6 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number CONTROLS TOP PANEL P16C0217 24 66 4 7 29 17 10 65 15 23 53 58 57 59 47 48 61 61 ...

Страница 16: ...134028500 Wiring Harness controls 134310100 Wiring Harness main 24 131970200 Button push start white 29 131666969 Console frame w trim tape 47 134274000 Meter Case assy 47 5304435395 Mounting Hardware meter case security 48 134028000 Gasket meter housing 53 134086822 Panel dryer top white coin op 57 3205253 Screw pan head 6 20B X 0 375 58 131863800 Retainer button plug 59 131863700 Plug button 61 ...

Страница 17: ...10 03 8 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number MOTOR 47 52 10 34 15 4 28 27 11 20 23 34 7 46 25 P16M0027 22 52 48 51 ...

Страница 18: ...11 131749800 Spacer idler 15 131298300 Thermostat temp control 20 131017900 Screw hex head 1 4 20T x 1 25 spacer mtg thread cutting 22 131601000 Spring idler arm 23 131863002 Idler Arm Assy w pulley clip 25 134163400 Belt dryer 27 134242400 Clamp motor mtg 28 131560100 Motor main drive w pulley 34 131243700 Screw pan head 8 18AB x 0 375 cr sq drive 46 134203400 Bracket motor mtg 47 131633300 Seal ...

Страница 19: ...10 03 10 417 64182300 CAUTION Use the Kenmore part number to order parts not the illustration number WIRING DIAGRAM ...

Страница 20: ......

Отзывы: