background image

9

Air Directional Louvers

Air directional louvers control air flow direction. Your air conditioner has the 
8-way directional system described below.

The louvers will allow you to direct the air flow Up or Down and Left or Right
throughout the room as needed. Rotate the Auger Wheels until the desired 
Left or Right direction is obtained. Pivot horizontal louvers with your fingertips 
until the desired Up/Down direction is obtained. There are a total of 8 possible 
air directional orientations available with this system. 

Care and Cleaning

Clean your air conditioner occasionally to keep it looking new. 

Be sure to 

unplug the unit before cleaning to prevent shock or fire hazards

.

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is
necessary.
Trapped particles in the filter can build up and block air from flowing to 
cooling coils and cause an accumulation of frost on the cooling coils.

On models with Fresh Air Vent Control, push in control to vent closed position.
Open the front panel.
Grasp the filter by the center and pull up and out.
Wash the filter using liquid dishwashing detergent and warm water. Rinse
filter thoroughly. Gently shake excess water from the filter. Be sure filter is
thoroughly dry before replacing.
Or instead of washing, you may vacuum the filter clean.

Cabinet Cleaning

Be sure to unplug the air conditioner to prevent shock or fire hazard. The
cabinet and front may be dusted with an oil-free cloth or washed with a
cloth dampened in a solution of warm water and mild liquid dishwashing
detergent. Rinse thoroughly and wipe dry.

Never use harsh cleaners, wax or polish on the cabinet front.

Be sure to wring excess water from the cloth before wiping around the 
controls. Excess water in or around the controls may cause damage to the
air conditioner.
Plug in air conditioner.

Winter Storage

If you plan to store the air conditioner during the winter, remove it carefully
from the window according to the installation instructions. Cover it with cloth
or return it to the original carton.

Energy Saving Ideas

The capacity of the room air conditioner must fit the room size for efficient
and satisfactory operation.
Install the room air conditioner on the shady side of your home. A window
that faces north is best because it is shaded most of the day.
Do not block inside airflow around air conditioner with blinds, curtains or 
furniture; or outside with shrubs, enclosures, or other buildings.
Close the fireplace damper, floor and wall registers so cool air does not 
escape up the chimney and into the duct work.
Keep blinds and drapes in other windows closed during the sunniest part of
the day.
Clean the air filter as recommended in the section “Care and Cleaning.”
Proper insulation and weather stripping in your home will help keep warm air
out and cool air in.
External house shading with trees, plants or awnings will help reduce the
air conditioner’s work load.
Operate heat producing appliances such as ranges, washers, dryers and
dishwashers during the coolest part of the day. 

NOTE: Store air conditioner in a dry place in upright position (horizon-
tal with base down).

Tab

Air Filter

NOTE: 

 When replacing the air filter after cleaning, make sure the tabs on 

the air filter are on the upper part of filter, and placed outward as shown in 
the drawing on the left side.

AUGER WHEELS

LOUVERS

Car

e & 

Cleaning

Содержание 253.35006

Страница 1: ...enmore CLIMATISEUR DE TYPE FENÊTRE Sears Brands Management Corporation Hoçman Estates IL 60179 U S A www kenmore com www sears com English Français Use Care Guide Manuel d utilisation et d entretien Models Modèles 253 35305 253 35308 253 35310 253 35312 ...

Страница 2: ...ted to filters 2 Service related telephone calls or technician visits relating to a user s requirements for instructions involving the correct product installation operation or regular maintenance to the product i e cleaning filters and the like 3 Maintenance adjustments and cleaning inquiries or service calls 4 Damage or failure when installation operation and maintenance instructions provided ar...

Страница 3: ...t connecting tubing and the compressor will be covered free of charge if defective in material or workmanship 3 If this appliance is ever used for other than private family residential purposes this warranty only applies for 30 days from the date of purchase Service Type Kenmore window and portable air conditioner units are serviced on a carry in basis whereby customer brings the unit to a Sears R...

Страница 4: ...ars at 1 800 4 MY HOME Prevent Accidents To reduce the risk of fire electrical shock or injury to persons when using your air conditioner follow basic precautions including the following If the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track type with a screen panel included remove the screen completely be...

Страница 5: ...tery in tray with POSITIVE side facing UP according to diagram Re insert battery tray TO REPLACE BATTERY Battery Size CR2025 ACTIVATES TIMER SLEEP MODE FILTER RESET BUTTON TURNS UNIT ON OR OFF ADJUSTS TEMPERATURE OR TIME SETS FAN SPEEDS DISPLAYS TEMPERATURE TIME SETS MODE REMOTE CONTROL ON OFF ADJUSTS TEMP TIME AUTO FAN SLEEP MODE SETS FAN SPEEDS ACTIVATES TIMER INFRARED REMOTE WINDOW TAB CAUTION ...

Страница 6: ...t will automatically go to the highest speed The fan speed will re adjust back to the slowest speed as the room returns to the original set temperature To operate on Fan Only press the MODE button to select Use Fan Only function to circulate room air without air conditioner cooling You can use any fan speed you prefer and the actual room temperature will be displayed in the DISPLAY To use Cool pre...

Страница 7: ... will save energy usage in this mode The compressor and motor will turn off once the room is at the desired temperature The air will be sampled for 20 seconds every 10 minutes until the room is above the set temperature at which point the compressor turns back on and the fan runs The entire process is now repeated Press the UP and DOWN arrows to select the desired time up to 24 hrs The control wil...

Страница 8: ...h a key hole overflow drain hole can use drain kit 5304481680 to connect a 1 2 inch drain hose for safe disposal of excess system water This part can be ordered at www SearsPartsDirect com There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY This is to cover the possibility of having to roll through to select another mode FRESH AIR VENT CONTROL On 253 35310 253 35312 ...

Страница 9: ...ughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation...

Страница 10: ...E AIR CONDITIONER TURNS ON AND OFF BY ITSELF Check if Then Outside temperature is extremely hot Set fan speed at the fastest setting for maximum cooling Page 6 Timer turned unit ON or shut unit OFF Push ON OFF Button to turn unit ON or OFF Page 6 THE AIR CONDITIONER DOES NOT COOL THE ROOM ICE BEHIND FRONT PANEL Check if Then Outside temperature is below 16 C Set mode to FAN ONLY and fan speed to f...

Страница 11: ...gerant passing through evaporation Page 11 Gurgling or hissing sounds Beeping Electronic Control Normal noise when electronic control settings are changed Vibration Unit Vibration Due to poor wall or window construction or incorrect installation Page 11 Room Air Conditioner Troubleshooting Guide Normal Sounds High Pitched Whine Today s high efficiency compressors may have a high pitched whine duri...

Отзывы: