Содержание 16025628

Страница 1: ...ization No Load Performance Controls in Normal Position Refrigerator Center Compartment Freezer Compartment Percent Run Time Average Food Average Food Kw 24 hr _ 0 4 _ 10 Cycles 24 hr _ 25 Temperature _ 3 F Temperature _ 3 F Ambient F 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 22 cuft 1 2 1 85 2 6 35 55 75 24 24 19 37 39 42 0 0 2 23 cu ft 1 2 1 85 2 6 35 55 75 24 24 19 37 39 42 0 0 2 26 cuf...

Страница 2: ... leads 1Olohms 10 Service Specifications I WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization Programming Mod...

Страница 3: ...efrigerator display and keypad Enter the Service Test Mode by performing the following sequence of events 1 Open the Fresh Food door and press and hold the Door Alarm Keypad 2 Press and hold Refrigerator Temperature UP Keypad _ 3 Release the Door Alarm Keypad and wait 3 seconds L Freezer Or_r _p _0_ _ _ _ Refrigerator S 4 Press the Refrigerator Down Keypad L _T_J again 5 Display will show 001 in l...

Страница 4: ...r open thermistor or SH for shorted thermistor Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor Service Test 143 Machine Compartment Thermistor Will Show Machine CompartmentTemperature or OP open thermistor or SH shorted thermistor Service Test 151 Fresh Food Door State Will show state of Fresh Food Door OP open CL closed NOTE...

Страница 5: ...e ON or OFF NOTE By pushing Actuator pad or Bottle fill you can change state of Dispenser Line Service Test 181 Keypad Operation Display shows a numeric or letter display indicating the last key pressed NOTE Refrigerator Up Down keypads have no effect when pressed and Freezer Up Down keypads remain operational Service Test 182 LED Indicator Operation Press the Refrigerator Up Keypad_ to show opera...

Страница 6: ...ury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization 12921601 PRINTED I U SA December 2004 8 12893007 ...