Страница 1: ...s could result in death or serious injury Instruction manual must remain with water heater Si no puede leer o entender el ingles y necesita el manual instructivo y o etiquetas en espaffol puede obtenerlos Ilamando al 1 800 821 2017 NO TRATE DE INSTALAR O OPERAR ESTE CALENTADOR DEAGUAsi no entiende la informaci6n en las etiquetas o en el manual instructivo No hacer case de esta advertencia podria r...

Страница 2: ... WARNmNG indicates a potentially hazardous situation which if not avoided could result in death or injury CAUTmON indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTLON used without the safety aJert symbo indicates a potentially hazardous situation which if not avoided could result in property damage AH safety messages will generally tell yo...

Страница 3: ... plate Maintain required clearances to combustibles_ Keep ignition sources away from faucets after a extendedperiodofnon use Read instruction manual before installing using or servicing water heater Explosion Hazard o Overheated water can cause water tankexplosion o Properly sized temperature and pressure relief valve must be installed in opening provided Breathing Hazard o Carbon Monoxide Gas Ins...

Страница 4: ...the Water Heater 14 15 Venting 15 16 Gas Piping 16 17 Sediment Trap 17 OPERATING INSTRUCTIONS 18 19 Lighting Operating Label 18 Temperature Regulation 19 SERVICE AND ADJUSTMENT 20 22 Tank Sediment Cleaning 20 Venting System Inspection 20 Burner Inspection 20 Burner Cleaning 20 Housekeeping 20 21 Anode Rod Inspection 21 Temperature Pressure Relief Valve Operation 21 Draining 21 22 Drain Valve Washe...

Страница 5: ...ymarch Park Quincy MA 02269 If after reading this manual you have any questions or do not understand any portion of the instructions call the Sears Service Center Carefully plan the place where you are going to put the water heater Correct combustion vent action and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires See figure 1 Examine ...

Страница 6: ...EXPANSION TANKS FOR THERMAL EXPANSION CONDiTiONS AVAILABLE IN 2 GALLONS 7 6 L_TERS AND 5 GALLONS 118 9 LITERS CAPAC TYTHROUGH LOCAL SEARS STORE OR SERVICE CENTER Basic Tools You may or may not need al these tools depending on your type of installation These tools can be purchased at your local Sears Store Pipe Wrenches 2 14 356 ram Screwdriver Tin Snips 6 1 82 m Tape or Folding Ruler Garden Hose D...

Страница 7: ...t offVaIve Q TemperatureoPressure Re iefVaIve Z Piezolgniter Ground Joint Union R RatingP ate AA Air ntake Screen iNSTALL tN ACCORDANCE WiTH LOCAL CODES DRmP LEG AS REQUIRED BY LOCAL CODES TO VENT TERMiNATiON ON ROOF x UNSTALL THERMAL EXPANSION TANK OR DEVRCE UFWATER HEATER IS INSTALLED IN A CLOSED WATER SYSTEM w Q R _m THERMOSTAT SHIELD OPTIONAL T THERMOSTAT GAS CONTROL KNOB L WATER TE_ _PERATURE...

Страница 8: ...r In most installations the vent pipe can be lifted off after any screw or other attached devices are removed Dispose of the draft hood The new water heater has a draft hood which must be used for proper operation If have to the water the two you copper piping heater copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater see Figure 6...

Страница 9: ...use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Avoid all ignition sources if you smell LP ga Do not expose water heater control to excessive gas pressure Use only gas shown on rating plate Maintain required clearances to combustibles Keep ignition sources away from faucets after extended period of non use Read instruction manual before installing ...

Страница 10: ... with respect to insulation and standby loss requirements making an insulation blanket unnecessary Breathing Hazard Carbon Monoxide Gas Do not obstruct water heater air intake with insulating blanket Gas and carbon monoxide detectors are available Install water heater in accordance with the instruction manual Breathing carbon monoxide can cause brain damage or death Always read and understand inst...

Страница 11: ...quare inch per 1 000 Btu per hour 22 cm2 kW of the total input rating ofal gas utilization equipment in the confined space but not less than 100 square inches 845 cmZ One opening shall commence within 12 inches 30 cm of the top and one commencing within 12 inches 30 cm of the bottom of the enclosures NT bottom of the enclosure The openings shall communicate directly or by ducts with the outdoors o...

Страница 12: ...ome people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest p...

Страница 13: ...eaded end of the threadedoto sweat coupling and around both ends of the 3 4 NPT threaded nipple Using flexible connectors connect the hot water pipe to the hot water outlet on the water heater Look at the top of the water heater The cold water inlet is marked COLD Put two or three turns of teflon tape around the threaded end of the threadedoto sweat coupling and around both ends of the 3 4 NPT thr...

Страница 14: ... OUTLET RELIEF VALVE OPTIONAL TOP T P REMEF VALVE NOT SHOWN DmSCHARGE PmPE DO NOT CAP OR PLUG FLOOR DRAIN FIGURE l Water Damage Hazard Temperature pressure relief valve discharge pipe must terminate at adequate drain The Discharge Pipe Shall not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restrictions Shall not be plugged or blocked Shall be of...

Страница 15: ... with NFPA 54 Be alert for obstructed or detedoo rated vent system to avoid serious iniun or death Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual To insure proper venting of this gas fired water heater the correct vent pipe diameter must be utilized Any additions or deletions of other gas appliances on a common vent with this water heater ma...

Страница 16: ...The minimum inlet gas pressure listed on the rating plate is for the purpose of input adjustment If the gas control valve is subjected to pressures exceeding 1 2 pound per square inch 3 5kPa the damage to the gas control valve could result in a fire or explosion from leaking gas If the main gas line shutoff serving a gas appliances is used also turn OFF the gas at each appliance Leave all gas appl...

Страница 17: ...e bottom outlet or other device recognized as an effective sediment trap If a tee fitting is used it shall be installed in conformance with one of the methods of installation shown in Figures 19 and 20 Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum Propane LR gases The appliance and its gas connection must be leak tested before placing the appliance in ...

Страница 18: ...e turned from PILOT to OFF unless it is pushed down slightly Do not force Remove the outer burner door located below the gas control Wait five 5 minutes to clear out any gas If you then smell gas STOPt Follow B in the safety information above on this label if you don t smell gas go to next step This unit is equipped with a push button pilot igniter which is used to light the pilot Locate the ignit...

Страница 19: ...dicative of approximately 120 F 49 C is preferred starting point Some states have a requirement for a lower setting Turn the water temperature dial clockwise _ to decrease the temperature or counterclockwise _ to increase the temperature Should overheating occur or the gas supply fail to shut off turn off the manual gas control valve to the appliance HOTTER WATER CAN SCALD Water heaters are intend...

Страница 20: ...least once a year a visual inspection should be made of the venting system You should look for Obstructions which could cause improper venting The combustion and ventilation air flow must not be obstructed Damage or deterioration which could cause improper venting or leakage of combustion products Rusted flakes around top of water heater Be sure the vent piping is properly connected to prevent esc...

Страница 21: ...rating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with a new one If the temperature pressure relief valve on the appliance weeps or discharges periodically this may be due to thermal expansion You may have a check valve installed i...

Страница 22: ... OFF gas supply to water heater 2 Follow Draining instructions 3 Turning counter clockwise _ remove the hex cap below the screw handle 4 Remove the washer and put the new one in place 5 Screw the handle and cap assembly back into the drain valve and retighten using a wrench DO NOT OVER TIGHTEN 6 Follow instructions in the FiihtTg The Water Heater section 7 Check for leaks 8 Follow the lighting ins...

Страница 23: ... are available from Sears stores and through the Sears Service Centers Contact the local plumbing inspector water supplier and or the Sears Service Center for assistance in controlling these situations see Figure 26 Therma Expansion Tank Specifications Model Number 153 331020 153 331050 Tank Dimensions Capacity in Inches In GaJJons Diameter Length 2 8 203 ram 12 3 4 323 ram 5 11 279 mm 14 3 4 375 ...

Страница 24: ...ment if the smelly water persists after the anode replacement and chlorination treatment we can only suggest that chlorination or aeration of the water supply be considered to eliminate the water problem Do not remove the anode leaving the tank unprotected By doing so all warranty on the water heater tank is voided AIR In Hot Water Faucets Explosion Hazard Flammable hydrogen gases may be present K...

Страница 25: ...from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area E The temperature pressure relief valve may be leaking at the tank fitting R Water from a drain valve may be due to the valve being slightly opened G The drain valve may be leaking at the tank fitting m_ Combustion products contain water vapor which can condense on the cooler surfaces of the ...

Страница 26: ...pressure Incoming water is unusually cold Leaking hot water pipes or fixtures High temperature limit switch activated Thermostat set too high Condensation dripping on burner Sediment or calcium in bottom of heater tank Improper combustion Lack of supply air Improperly installed vent piping Downdraft Poor combustion Tighten threaded connections Inspect other appliances near water heater Refer to CO...

Страница 27: ...405 9003464 9001584 9003480 9003445 F145 1278 9003500 9003981 9003398 9003401 184232 001 23600 9003719 9003545 9003410 9003542 9003484 F145 1280 9003414 153 339261 9003406 9003487 9003379 9003385 9003493 33 9003389 9003405 9003464 9001584 9003480 9003445 F145q278 9003500 9003981 9003398 9003401 184232 001 23600 9003719 9003545 9003410 9003530 9003484 F145 1280 9003414 153 339411 HA 9003406 9000734...

Страница 28: ...9 9003463 9003981 9003392 9003401 184232o001 23600 9003916 9003545 9003410 9003541 9003484 F145 1280 9003414 Model Numbers 153 339111 HA 9003406 9003928 9003724 9003385 9003492 35 9003726 9003405 9003911 9001584 9003994 9003445 F145 1293 9004131 9002277 9003398 9003401 184232o001 23600 9003719 9003409 9003410 9003540 9000728 F145 1280 9003414 153 339160 9003406 9003928 9003991 9003385 9003493 33 9...

Страница 29: ... 1278 9003473 9003981 9003454 9003401 184232 001 23600 9003719 9003409 9003410 9003542 9003484 F145 1280 9003414 Model Numbers 153 339561 9003406 9003932 9003382 9003385 9003493 33 9003389 9003405 9003482 9001584 9003403 9003445 F145 1278 9003473 9003981 9003454 9003401 184232o001 23600 9003719 9003409 9003410 9003530 9003484 F145 1280 9003414 153 339761 9003406 9003932 9003380 9003421 9003494 3 9...

Страница 30: ...30 ...

Страница 31: ...31 ...

Страница 32: ...entive maintenance or repair from time to time That s when having a Master Protection Agreement can save you money and aggravation Purchase a Master Protection Agreement now and protect yourself from unexpected hassle and expense The Master Protection Agreement also helps extend the life of your new product Here s what s included in the Agreement o Expert Service by our 12 000 professional repair ...