Страница 1: ... other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical sw_tch do not use any phone in your building i Immedlately call your gas supplier from a neighbor s phone Follow the gas supplier slnstructions If you can not reach your gas suppher call the fire department Installation and service must be performed by a qualified installer service agency or ...

Страница 2: ... meeting the requirements for Relief Valves and AutomaticGasShutoffDevices for Hot Water Supply Systems and the latest edition of ANSI Z21 22 and the code require mentsof ASME If replaced the valvemustmeet the require ments oflocalcodes but notlessthan a combination tempera ture and pressure rellef valvecertifiedas meeting the require mentsfor ReliefValvesandAutomaticGasShutoffDevices for Hot Wate...

Страница 3: ...E I AWARNING VENT DAMPERS Any vent damper whether it is operated thermally or otherwise mustbe removedif itsuseinhibits prep er draftingofthe water heater Thermally Operated Vent Dampers Gas firedwater heaters havingthermal efficiency in excess of 80 mayproducea rela tively lowfluegastemperature Suchtemperaturesmaynot be high enough to properly open thermally operated vent damper_ Thiswouldcausesp...

Страница 4: ...sions and must be piped to an adequatedrain The panmustnot restrictcombustion air flow Under no circumstances isthe manufacturer or Searsto be held liablefor any water damagein connection with this water heater WARNING HYDROGEN GAS Hydrogengas can be producedin a hot water systemthat hasnot beenusedfor a longperiod of time generallytwo weeksor more Hydrogen gasis extremely flammableand explosive T...

Страница 5: ...sion Instructions 16 17 Installation Checklist 18 O eratin Instructions 19 21 g _iig_ting 19 20 Temperature Regulation 21 Service and Adjustment 22 23 Tank Sediment C eaning 22 Burner Inspection 22 Burner Cleaning 22 Draining _ 22 Temperature Pressure Relief Valve Operation 23 Drain Valve Washer Replacement 23 Housekeeping 23 Service 23 Troubleshooting Guide 24 25 Start Up Conditions 24 Thermal Ex...

Страница 6: ...r heater and your safety Since we cannot put everything on the first few pages READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER The gas fired water heater is design certified by the American Gas Association Laboratories under American National Standards for Gas Water Heaters for Installation in ManufacturedHouses Mobile Homes Instructions to Mobile Home Manufacturers...

Страница 7: ... PANS AVAILABLE IN 20 DIAMETER FOR WATER HEATERS HAVING A DIAME TER 18 OR LESS AND AVAILABLE IN TRAPS HELP REDUCE HEAT 28 DIAMETER FOR WATER HEATERS LOSS DUE TO THERMAL HAVING A DIAMETER 26 OR LESS SYPHONING Basic Tools You may or may not need all of these tools depending on your type of installation These tools can be purchased at your local Sears store Pipe Wrenches 2 14 Screwdriver Tin Snips 6 ...

Страница 8: ...two copper water pipes can be cut with a hacksaw approximately 4 away from where they connect to the water heater This will avoid cutting off the pipes too short Additional cuts can be made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drain valve The water heater is now completely ...

Страница 9: ...itioned a maximum of 6 above the lower edge of the access door and which may incorporate either V4 wire mesh or louvers When V4 wire mesh is used the size of the opening must be a mini mum of 20 square inches When the louvers are used the area must be a minimum of 20 square inches INSTALLATION METHOD B An optional enclosure ncorporating a solid exter or access door when a 5 or 8 diame ter or 20 sq...

Страница 10: ...to ConsiderAbout the Location sectionof this manualandalso the latesteditionofthe NationalFuelGasCode ANSI Z223 1 also referredto as NFPA 54 for specifics providedconcerning air required AWARNING I Toxicchemicals suchasusedfor meatment of boilersor non I potablewater heatingappliances shall neverbeintroduced into a potablewaterheatingsyster_ A CAUTION WATER HEATERSEVENTUALLY LEAK Installationof th...

Страница 11: ...s your hotwater needs a meanssuch asamixingvalve shouldbeusedat the hotwater tapsusedby these peopleor at the water heater Mixingvalves are available at plumbing supply or hardware store_Followman ufacturersinstructionsfor installationof the valves Before changingthe factory setting on the thermostat read the TemperatureRegulation section inthbmanual MOUNTING BRACKET BRACKETS WARNING This water he...

Страница 12: ...INSTALLATION KIT WATER PIPING PRESSURE TEST This section is only for the mobile home manufacturer installing the water heater when the installation is to comply with H U D Standards When testing the water ways H U D Standards state Water distribution system All water piping in the water dis tribution system shall be subjected to a pressure test The test shall be made by subjecting the system to ai...

Страница 13: ...No valveor other obstruction isto be placedbetweenthe relief valveand the tank Do not connecttubingdirectlyte discharge drainunless a6 airgapisprovided Topreventbodilyinjury haz ardto life or propertydamage the relief valvemust be allowed to discharge water inquantities should circumstances demand If the discharge pipeisnot connected to a drainor other suitable means the waterflowmaycause property...

Страница 14: ...cally actuat ed vent dampers Before installation of any vent damper consult the local Sears Service Center or gas utility for further information AWAIRNING To insureproper ventingof this gas firedwater beater the correctvent pipe diameter mustbe utilized Anyadditions or deletionsof other gasappliances ona common ventwith this water heater may adversely affectthe operationofthe water heater Consult...

Страница 15: ... acUonofpetroleum Propane L P gase_ J A gas line of sufficient size must be run to the water heater Consult the latest edition of National Fuel Gas Code ANSI Z223 1 also referredto as NFPA54 and the gas company concern ing pipe size There must be A readilyaccessible manual shut off valvein the gas supply line serving the waterheater and A drip leg sediment trap ahead of the gas control valveto hel...

Страница 16: ...and turn counter clockwise _ to stop Con trol screw must be in IN position for propane L P gas and m OUT posmon for natural gas STOP Read label For Your Safety located on your water b _ater Step 9 Step 10 Step 11 Step 12 Step 13 Step 14 Step 15 Step 16 Step 17 Step 18 Step 19 Set the thermostat to lowest setting by turning the water temperature dial clockwise _ _ to its lowest temperature setting ...

Страница 17: ...control valve The indicated gas may be either Natural or Propane LR By followingthe conversioninstructions in this manual or the instructionsnear the gas control valve the water heater must be converted if it is to be used with the opposite gas DO NOT USE THIS WATER HEATER WITH ANY GAS OTHER THAN THE ONE LISTED ON THE MODEL RATING PLATE Failure to use the correct gas can cause problems which can r...

Страница 18: ...UL LISTED ROOF JACK TEMPERATURE PRES SURE RELIEF VALVE SHUTOFF VALVE Will a water leak damageanything See the Facts to Consider About the Location section TEE COLD COLD Is there proper clearance between the water heater and any thing that might catch fire See the Facts to Consider About the Location section Do you have adequate ventilation so that the water heater will operate properly See Combust...

Страница 19: ...enleavethe premise_ Lighting and operating instructions are located on front of the water heater above or to one side of the gas control valve Figure 5 AWARNING AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER FORYOUR SAFETY IFYOU SMELLGAS Do nott_ to lightanyappliance Do not touchony electrkudswitch do not usuany phonein your building Immediatelycallyourgassupplierfrom a neighbor s phone ...

Страница 20: ...rmation aboveon this label If you don t smellgas goto the nextstep 5 Remove or open inner door locatedbelow the gas controlunit Figure8 page19 Findpilot follow metaltube fromgas control Thepilot is locatedonthe righthandsideof the burner PILOT BURNER _THERMOCOUPLE 8 If youdon tsmellgas turnknobongascontrolcounter f_ to PILOT position Figure 6 clockwise page19 9 Push in control knob all the way and...

Страница 21: ...sedby these peopleor at the water heater Mixingvalves areavailable at plumbing supply or hardware store_ Followman ufacturarsinstructionsfor installationof the valves Before changingthe factory setting on the thermostat read the _emperatureRegulation section inthis manual Turn the water temperature dial clockwise f _ to decrease the temperature or counterclockwise _ _ to increase the temperature H...

Страница 22: ...all the localgasu_ity to correctthe problemand cleanor replacethe flueandvehtingI I beforeresumingoperationof the water heater I Burner Inspection AWARNING I Do not usetl_ applhnce ifany part of _ _m beonunderwaist I Immediately call a Sears Service Technicianto inspectthe I appliance and to replace the gascontrol or any part of the I burner_ whichhasb_m underwater 22 Burner Cleaning In the event ...

Страница 23: ...ve installed in the water line or a water meter with a check valve Consultthe SearsServiceCenter for further informa tion Do notplugthe temperature pressure raliefvaJve AWARNING When checl6ngthe temperatore pressure_qief valveopera tion make surethat I no one is in freet of or areund the outlet of the temperature pressure reliefvalvedischarge line and 2 that the water manuallydischarged will not c...

Страница 24: ...s Service Center for assistance in controlling these situations Thermal Expansion Tank Specifications Model Number 153 331020 153 331050 Tank Capacity Dimensions in Inches In Gallons Diameter Length 2 8 inches 12_ inches 5 11 inches 14_ inches Pipe Fitting On Tank _ Male _ Male HOT COLD WATER HEATER COLD WATER bINLET FITTING WATER HEATER COLD WATER INLET FITTING HOT O PRESSURE REDUCING VALVE WITH ...

Страница 25: ...essive condensation may be noticed during the winter and early spring months when incoming water temperatures are at their lowest Smelly water may be eliminated or reduced in some water heater models by replacing the anode s with one of less active material and then chlorinating the water heater tank and all hot water lines Contact Sears Service for further information concerning an Anode Replacem...

Страница 26: ...ting instructions in this manual or located above the gas control valve on the water heater to telight the pilot If the water was extremely hot and is now cold the high limit safety temperature shut off may have put out the burner and pilot If the high temperature shut off activates the gas controlvalve must be replaced Contact the Sears Service Center The gas control knob must be turned to the ON...

Страница 27: ...y be leaking Small amounts of water from temperature pressure relief O valve may be due to thermal expansion or high water pres sure In your area O The temperature pressure relief valve may be leaking at the tank fitting O Water from a drain valve may be due to the valve opened slightly Q The drain va ve may be leaking at the tank fitting O Combustion products contain water vapor which can con den...

Страница 28: ...Parts Order List THE ECONOMIZERm6MOBILEHOMEGASWATERHEATERS MODEL NUMBERS 153 333831 30Gal 153 333931 40GaL I I 17 _ 18 1 _14 13 7 28 ...

Страница 29: ...00351 9000281 9000281 F145 0846 F145 0846 F145 0697 F145 0697 9000391 9000537 9000272 9000272 9001261 9001261 0002915370 23600 Not Illustrated These parts are also available at most Sears retail stores Also available at most hardware stores t Replaced only upon return of damaged plate Now that you have purchased your Gas Water Heater should a need ever exist for repair parts or service simply cont...

Страница 30: ...Notes 30 ...

Страница 31: ...Notes 31 ...

Страница 32: ...he One Year Limited Labor Warranty below there will be acharge for installation ONE YEAR LIM1TED LABOR WARRANTY ON WATER HEATER When your Sears Kenmore water heater is installed by Sears or its licensed subcontractor and is operated in accordance with the instructions in this manual Seam will for one year from the date of purchase Install free of charge the replacement water heater as provided by ...