6
Note:
Fan must be installed at a maximum
distance of 20 feet from the transmitting unit
for proper signal transmission between the
transmitting unit and the fan's receiving unit.
7. INSTALLATION OF
SAFETY SUPPORT
Attach the lag bolt and flat washer to ceiling
joist. Attach the safety cable to lag bolt. Slide
cable clamp onto safety cable (from fan).
Place the end of cable through the lag bolt.
Pull as much cable through lag bolt as
possible. Feed end of cable into clamp hole
and firmly tighten screw (Figure 12). Cut off
excess safety cable.
8. FINISHING THE
INSTALLATION
Step 1. Tuck connections neatly into ceiling
outlet box.
Step 2. Slide the canopy up to hanger bracket
and place the key hole on the canopy over the
screw on the hanger bracket, turn canopy until
it locks in place at the narrow section of the
key holes. (Fig.13)
Step 3. Align the circular hole on canopy with
the remaining hole on the hanger bracket,
secure by tightening the two set screws.
Note:
Adjust the canopy screws as necessary until
the canopy and canopy cover are snug.
WARNING:
Make sure tab at bottom of
hanger bracket is properly seated in groove of
hanger ball before attaching canopy to
bracket. Failure to properly seat tab in groove
could cause damage to electrical wiring.
Figure 12
Figure 13
Outlet box
Hanger
bracket
Canopy
Canopy cover
Screws
Hanger bracket
Safety cable
Safety cable clamp