background image

6

Now using the X-axis knob set for split screen, one can view the left

microscope specimen on the left, the right microscope specimen on the
right, or roll the knob and see only the left or the right specimens.

Specimen Manipulation

The T-1924C comes with a "floating stage".  Place the specimen on

the stage (use stage clips for a microscope slide), and then grasp the
stage between the thumb and forefinger, and move the whole stage,
specimen and all, left-right, forward-backward.  Because of the
lengthened working distance of this microscope, it is not practical to have
a mechanical stage.

Seidentopf Binocular Head

The Cordless Comparison Scope has two eyepieces with a diopter

on one eyepiece to compensate for differential visual acuity between an
individual's eyes.  The Seidentopf binocular head allows adjustment for
interpupillary (interocular) adjustment.  The eyepieces will move to
exactly match the distance between the user's eyes.

Care and Maintenance

Your microscope is a fine precision instrument and should be treated

with care.  When not in use, it should be protected from dust by the plastic
cover provided.  Lenses and eyepieces should be cleaned periodically
with optical lens tissue which is soft and lint free.  Painted surfaces can be
cleaned with a moistened cloth.

Ken-A-Vision has quality technicians on staff to repair or service your

microscopes.  Ken-A-Vision recommends service every two years for
optimal life of the product.  Contact Ken-A-Vision at 1.816.353.4787,
Extension 5620 for more details.

Technical Specifications for Model No. T-192X Series
Microscopes

For the technical specifications on the Cordless Comparison Scope

visit the Ken-A-Vision Web site, www.ken-a-vision.com /t1922.asp

Содержание Comparison Scope T-1924C

Страница 1: ...Cordless Comparison Scope Instruction Manual T 1924C...

Страница 2: ...or opaque objects in a manner similar to a stereo or dissecting microscope Both are shipped as cordless units with an enclosed charger power cord adapter The T 1924C has 2x 4x 10x and 40xR DIN objecti...

Страница 3: ...ft each microscope base out of shipping container Note that the serial numbers on the bottom of the units end in either an L left base or an R right base Remove all packing materials on stage and illu...

Страница 4: ...he socket sliding in from the right until it is flush in socket opening Tighten the set screw Step 6 Insert eyepieces into the eyetubes Step 7 Plug both microscopes into wall socket and allow them to...

Страница 5: ...comes through The floating stage can actually cover up the sub stage illuminator so no light comes through Place a specimen slide on the stage of the microscope and move the specimen into place for vi...

Страница 6: ...ual s eyes The Seidentopf binocular head allows adjustment for interpupillary interocular adjustment The eyepieces will move to exactly match the distance between the user s eyes Care and Maintenance...

Страница 7: ...el style center pin with a 5 5 volt 300mA output supply which may be used with 110v 220v 230v or 240v input systems The power supply charger is made exclusively for the Ken A Vision Cordless Microscop...

Страница 8: ...Y WARRANTY To replace the batteries loosen the silver thumbscrew in bottom of the base Drop the door down remove the battery cover and replace the batteries Accessories If you are interested in purcha...

Отзывы: