Kemppi Minarc 150 AU Скачать руководство пользователя страница 4

©

 

COPYRIGHT

 

KEMPPI

 

OY

4 – Minarc 150AU / 0411

Mains voltage

Never take welding machine inside the work piece (e.g. container or car). Never set the 
welding machine on wet surface. Replace faulty cables immediately, they create a danger 
to life and can cause a 

fi

 re. See that the connecting cable does not stick nor touch sharp 

edges or a hot welding piece.

Welding current circuit

Isolate yourself from the welding current circuit by wearing dry and undamaged protective 
clothing. Never work on a wet surface. Never use damaged welding cables. Never set 
neither electrode holder, earth clamp nor the welding cables on top of the power source 
or other electric equipment.

Welding fumes

Ensure adequate ventilation. Always take special measures when welding metals containing 
lead, cadmium, zinc, mercury or beryllium.

2. 

BEFORE YOU START USING THE UNIT 

2.1. UNPACKING

The unit is packed in durable packages, designed specially for it. Nevertheless, always 
before using the unit, make sure it was not damaged during transportation. Also check 
that you have received what you ordered and that there are instructions for it. NOTE! The 
packaging material of the products is suitable for recycling.

2.2.  PLACING THE UNIT

Place the unit on horizontal, solid and clean surface. Shield it from heavy rain and scorching 
sun. Make sure that cooling air circulates freely.

2.3. SERIAL 

NUMBER

Serial number of the unit is marked on the rating plate of the unit. The serial number makes 
it possible to trace product manufacturing series. You might need the serial number when 
placing spare parts orders or when planning maintenance.

2.4. MAIN 

COMPONENTS

Connect welding cable and earth cable to their connections on the power source. Mains 
cable and wall plug are already installed.

RAMIRENT

Содержание Minarc 150 AU

Страница 1: ...Operation instructions english 1910150AU MINARC 150 AU R A M I R E N T...

Страница 2: ...Connecting to power supply mains 5 2 6 Filler materials and equipment 5 3 USE 5 3 1 Welding processes 5 3 1 1 Manual Metal Arc welding MMA 5 3 1 2 TIG welding 6 3 2 Operating functions 6 3 3 Welding...

Страница 3: ...oid danger of electric shock VRD maintains open circuit voltage under 35 V Minarc tolerates a great fluctuation of input voltage and is thus suitable for work on sites using generator as well as to be...

Страница 4: ...nc mercury or beryllium 2 BEFORE YOU START USING THE UNIT 2 1 UNPACKING The unit is packed in durable packages designed specially for it Nevertheless always before using the unit make sure it was not...

Страница 5: ...ta 1 Use welding specifications given on electrode package 2 Check that you have selected the correct welding process before starting to weld 3 Check that welding cable and earth cable connections are...

Страница 6: ...switch never use the plug as a switch Signal light VRD safe ON A The machine is equipped with an OCV reduction circuit The signal light is lit when the circuit is activated and the unit is in working...

Страница 7: ...usually about half the diameter of the electrode core wire When arc is lit move the electrode slowly forwards tilting it to appr 10 15 pulling angle If necessary adjust the current value Shielding ga...

Страница 8: ...Arc is uneven and goes off Electrode gets stuck in weld pool Check welding settings and adjust when necessary See 3 Use Check that earth clamp is properly fixed and that contact surface is clean and t...

Страница 9: ...Electrodes diameter 1 5 3 25 mm Welding current control stepless Open circuit voltage VRD 30 V Open circuit power 10 W Efficiency 80 Power factor 0 60 140A 25 5 V Degree of protection IP 23C Temperatu...

Страница 10: ...i Kemppi Building Fraser Road Priory Business Park BEDFORD MK443WH ENGLAND Tel 0845 6444201 Fax 0845 6444202 e mail sales uk kemppi com KEMPPI FRANCE S A S A au capital de 5 000 000 F 65 Avenue de la...

Отзывы: