COPYRIGHT
KEMPPI
OY
Minarc/0244 – 9
5. TECHNICAL INFORMATION AND GUARANTEE
CLAUSES
5.1. TECHNICAL INFORMATION
Minarc 140
Minarc 110
Connection voltage,
1 ~ phase 50/60Hz
220V-10%...240V + 6%
220V-10%...240V + 6%
Connection capacity
35 % ED
140 A
50 % ED
110 A
100 % ED
100 A
80 A
Mains cable/fuse, delayed
2,5 mm
2
S /3,3 m 16 A
1,5 mm
2
S /2,0 m 13 A
Welding current range,
Metal arc welding (MMA)
10 A/20,5 V...140 A/25,6 V
10 A/20,5 V...110 A/24,4 V
Electrodes, diameter
Ø1,5...3,25 mm
Ø1,5...2,5 mm
Welding current control range stepless
stepless
Open-circuit voltage
85V
85V
Open-circuit power
<10 W
<10W
Ef
fi
ciency
80%
80%
Power factor
0,60 (140A/25,5 V)
0,60 (110A/24,4 V)
Degree of protection
IP 23C
IP 23C
Temperature class
B (130°C)/H (180°C)
B (130°C)/H (180°C)
Range of working temperature -20...+40°C -20...+
40°C
Range of storage temperature -40...+60°C -40...+60°C
Degree of protection
IP23C
IP23C
Norms
IEC 974-1
IEC 974-1
EN 50199
EN 50199
External dimensions:
length
305 mm
123 mm
height
250 mm (207 mm)
250 mm (207 mm)
Weight
4,2 kg (4,8 kg)
4,2 kg (4,6 kg)
The unit ful
fi
ls CE marking demands.