6. 

OrderinG numbers

KempGouge ARC 800 (incl. transport unit)

6284000

Connector cable

4 X 16 mm2, 5 m

W000869

Connector cable

4 X 16 mm2, 10 m

W003408

Earthing cable

95 mm², 5 m (DIX120)

61840951

Earthing cable

95 mm², 10 m (DIX120)

61840952

Earthing cable

120 mm², 5 m

61841201

Earthing cable

120 mm², 10 m

61841202

Remote control R10

6185409

7. 

teChniCal speCiFiCatiOns

KempGouge ARC 800
Connection voltage

3~ 50/60 Hz

400 V -15 ... +20%

Rated power

50% ED

44 kVA

100% ED

35 kVA

Primary current

50% ED I

1max

65 A

100% ED I

1

51 A

Connection cable

H07RN-F

4G16 (16 mm²)

Fuse (recommended)

63 A delayed

Idle power

 

120 W

Efficiency

 

0.90

Power factor

 

0.90

Load capacity at 40 °C

50% ED

800 A / 44 V

100% ED

600 A / 44 V

Current adjustment range

 

20 A – 800 A

Open circuit voltage

 

50 V

Gouging carbon

max. size ø 13 mm

Recommended pressure of the 

compressed air

500 – 700 kPa (5 – 7 bar)

Storage temperature range

 

-40 °C ... +60 °C

Operating temperature range

 

-20 °C ... +40 °C

EMC class

A

Minimun short circuit power Ssc of 

supply network *

7.6 MVA

Degree of protection

 

IP23S

Dimensions

(without/with transport unit)

Length

590/700 mm

Width

230/660 mm

Height

885/1,400 mm

Weight

94/115 kg

Maximum load of lifting lug

200 kg

* See paragraph 2.3.

12

KempG

ouge AR

C 800 / © Kemppi O

y / 1117

Содержание KempGouge ARC 800

Страница 1: ...sning Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation Fran ais Manual de instrucciones Espa ol Instrukcja obs ugi Polski...

Страница 2: ......

Страница 3: ...Operating manual English KempGouge ARC 800 Kemppi Oy 1117...

Страница 4: ...tomatic function test 8 3 3 2 Front panel indicators 8 3 4 Control panel functions 8 3 4 1 Adjusting the gouging current 8 3 4 2 Actual gouging current and voltage display 9 3 4 3 Restoring factory se...

Страница 5: ...ctions Disclaimer While every effort has been made to ensure that the information contained in this guide is accurate and complete no liability can be accepted for any errors or omissions Kemppi reser...

Страница 6: ...ately 1 3 1 Power source 6 3 A 6 3 A A4 A2 A5 A6 A7 A8 A9 A1 A3 A10 A10 A11 A9 Front view Rear view A1 Control panel A2 Main switch A3 Signal light I O A4 Thermal warning light A5 Gouging cable connec...

Страница 7: ...s cooling air flow Preferably site the machine above floor level for example on a suitable carriage unit Notes for positioning the machine The surface inclination should not exceed 15 degrees Ensure t...

Страница 8: ...at the rear of the machine and secure the cable with a cable clamp Remember to use isolation between the cabel and the cable clamp 3 Connect the leads to the connectors as seen in the picture 4 Fasten...

Страница 9: ...r positive connector in the power source depending on the connector used for the gouging cable see Connecting the gouging cable The recommended cross sections of the cable are listed in the table abov...

Страница 10: ...System functions If the system encounters a fault a fault code is shown on the display Implementation of factory settings or preset settings If the function test is successful the machine is ready fo...

Страница 11: ...the work piece The pressure of the compressed air required in carbon arc gouging is 500 700 kPa 5 7 bar Attach the gouging carbon maximum size 13 mm to the holder in such a way that the free length of...

Страница 12: ...terminal block or mains socket 4 5 Machine error codes The machine always checks its operation automatically during start up and reports any failures detected If failures are detected during start up...

Страница 13: ...o not use a pressure washing device 2 Check the electrical connections of the machine Clean any oxidised connections and tighten the loosened ones Check for the right tension before you start repairin...

Страница 14: ...A Connection cable H07RN F 4G16 16 mm Fuse recommended 63 A delayed Idle power 120W Efficiency 0 90 Power factor 0 90 Load capacity at 40 C 50 ED 800 A 44V 100 ED 600 A 44V Current adjustment range 2...

Страница 15: ...EN 13 KempGouge ARC 800 Kemppi Oy 1117...

Страница 16: ...Tel 33 1 30 90 04 40 Telefax 33 1 30 90 04 45 sales fr kemppi com KEMPPI GmbH Otto Hahn Stra e 14 D 35510 BUTZBACH DEUTSCHLAND Tel 49 6033 88 020 Telefax 49 6033 72 528 sales de kemppi com KEMPPI SP K...

Отзывы: