3.2.3.6. PFC Boost control circuitry
•
PFC control circuitry is located on the primary side. Auxliary transformer T003 supplies operating voltage for the PFC
control circuitry. The output voltage of the T003 is first rectified and then linear regulator is used to regulate auxiliary
voltage to 15V. PFC control IC N1 regulates DC-link voltage to approximately 370V
3.3. Main circuit diagram 253-, 323-models
3.3.1. Main circuit card Z001
3.3.1.1. EMC filter
•
Capacitors C5 - C7, C8 - C10, C19 - C21 and inductors T4 and L1 form an EMC filter
•
First part of the filter is three phase filter which is located before the three phase rectifier V2
•
Second part is DC filter (L1) which is located after three phase rectifier
3.3.1.2. Inrush current limiting
•
PTC resistor R1 limits inrush current when the power source is switched on
•
R1 is bypassed with relays K1 and K2 after DC link capacitors C17, C18 have been charged
•
Relays K1 and K2 are controlled with the microcontroller
3.3.1.3. IGBT driver
•
IGBT driver consists of gate transformers T2 and T3 and surrounding components
3.3.1.4. Current transformer T1
•
Current transformer T1 is monitoring primary current and stops power stage operation if current is raising too high
3.3.1.5. Main circuit
•
Main circuit topology is H-bridge. The H-bridge topology requires four power switches which are implemented using
IGBT module V2. The switching frequency of the H – bridge is 20 kHz
•
253 power source uses 50A module
•
323 power source uses 75A module
G1
G3
G2
G4
U
G1
U
G2
U
G3
U
G4
U
T1
U
G5
U
L1
G5
L1
U
G1
U
G3
U
G4
U
G2
U
T1
U
G5
U
L1
Approx
.. + 570 V
When IGBT-transistors
G1
and
G4
conduct, there is a positive voltage
U
T1
in main transformer
T1
primary and when IGBT-
transistors
G2
and
G3
conduct there is a negative voltage
U
T1
in main transformer primary. Power is adjusted by changing the
IGBT timings (PWM).
Содержание KEMPACT 181A
Страница 1: ...Kemppi Oy SERVICE MANUAL KEMPACT RA 181A 251R 251A 253R 253A 323R 323A 253MV 323MV...
Страница 4: ...SERVICE MANUAL KEMPACT RA_V_1 2 3 40 Kemppi Oy 1 PARTS OF MACHINE Kempact RA 253 323...
Страница 10: ...SERVICE MANUAL KEMPACT RA_V_1 2 9 40 Kemppi Oy 2 2 Main circuit diagrams...
Страница 11: ...SERVICE MANUAL KEMPACT RA_V_1 2 10 40 Kemppi Oy...
Страница 18: ...SERVICE MANUAL KEMPACT RA_V_1 2 17 40 Kemppi Oy...
Страница 40: ......