Flexlite TX
Operating manual - EN
6.5 Technical data TX 223 and TX 253
Flexlite TX
223G
223GS
223GVD13
253WS
Feature
Value
Type of cooling
Gas
Gas
Gas
Liquid
Coolant flow rate (l/min)
l/min
-
-
-
1
Coolant pressure (min)
MPa
-
-
-
0.1
Coolant pressure (max)
-
-
-
0.5
Arc striking voltage
kV
10
10
-
10
Rating of electrical components (remote, nominal)
V
10
10
10
10
mA
10
10
10
10
Type of connection
Gas/current
R1/4
R1/4
DIX 13 mm *
-
Control
4-pin
4-pin
-
4-pin
Coolant
-
-
-
R1/4 & R3/8
Electrode diameters
mm
1.0…4.0
1.0…4.0
1.0…4.0
1.0…4.0
Load capacity @ 40 % (Argon)
A
220
220
220
250
Load capacity @ 100 % (Argon)
A
-
-
200
Operating temperature range (°C)
°C
-10…+40 °C
-10…+40 °C
-10…+40 °C
-10…+40 °C
Storage temperature range
°C
-40…+60 °C
-40…+60 °C
-40…+60 °C
-40…+60 °C
Minimum cooling power at 1.0 l/min
kW
-
-
-
1.0 kW
Remote control
-
-
-
-
Neck type
70° angle
Rotating
70° angle
Rotating
* Use a separate gas hose for gas connection.
This equipment complies with standard IEC 60974-7.
© Kemppi
31
1920910 / 2039