Flexlite TX
Operating manual - EN
6.4 Technical data TX 165
Flexlite TX
165GF
165GS
165G
Feature
Value
Type of cooling
Gas
Gas
Gas
Coolant flow rate (l/min)
l/min
-
-
-
Coolant pressure (min)
MPa
-
-
-
Coolant pressure (max)
-
-
-
Arc striking voltage
kV
10
10
10
Rating of electrical components (remote, nominal)
V
10
10
10
mA
10
10
10
Type of connection
Gas/current
R1/4
R1/4
R1/4
Control
7-pin
7-pin
7-pin
Coolant
-
-
-
Electrode diameters
mm
1.0…4.0
1.0…2.4
1.0…4.0
Load capacity @ 40 % (Argon)
A
160
160
160
Load capacity @ 100 % (Argon)
A
-
-
-
Operating temperature range (°C)
°C
-10…+40 °C
-10…+40 °C
-10…+40 °C
Storage temperature range
°C
-40…+60 °C
-40…+60 °C
-40…+60 °C
Minimum cooling power at 1.0 l/min
kW
-
-
-
Remote control
Optional
Optional
Optional
Neck type
Bendable
Rotating
70° angle
This equipment complies with standard IEC 60974-7.
© Kemppi
30
1920910 / 2039