Flexlite GX
Operating manual - EN
6.5 Technical data: Flexlite GX 300A/400A/420A (water-cooled)
Flexlite GX
403W /
405W
405WS
428W
428WS
Feature
Welding process
MIG/MAG
MIG/MAG
MIG/MAG
MIG/MAG
Contact tip
M10x1
M10x1
M10x1
M10x1
Method of guidance
Manual
Manual
Manual
Manual
Type of cooling
Liquid
Liquid
Liquid
Liquid
Coolant flow rate (l/min)
1
1
1
1
Coolant max. pressure (bar)
5
5
5
5
Min. cooling power at 1.6l/min * (kW) IEC 60974-7
0.9
0.9
1.9
1.9
Min. flow rate (l/min)
1
1
1.6
1.6
Type of connection
Euro
Euro
Kemppi
Kemppi
Wire diameters (mm)
0.8...1.6
1.0...1.6
0.8...1.6
1.2...1.6
Load capacity:
35% / Ar + 18% CO₂
-
-
-
-
60% / Ar + 18% CO₂
-
-
-
-
100% / Ar + 18% CO₂
400 A
300 A
420 A
300 A
35% / CO₂
-
-
-
-
60% / CO₂
-
-
-
-
100% / CO₂
-
-
-
-
Gas flow (l/min) in load capacity test
20
20
20
20
Filler wire diameter in load capacity
test
1.6
1.6
1.6
1.6
Stick out length in load capacity test
22
22
22
22
Filler wire diameters (mm):
Fe
0.8...1.6
-
0.8...1.6
-
Fe-MC/FC
0.9...1.6
-
0.9...1.6
-
Ss
0.8...1.6
1.0...1.2
0.8...1.6
1.2...1.6
Ss-MC/FC
0.9...1.6
-
0.9...1.6
-
Al
0.8...1.6
1.2...1.6
0.8...1.6
1.2...1.6
Operating temperature range
-
20°C…+40°C
-
20°C…+40°C
-
20°C…+40°C
-
20°C…+40°C
Storage temperature range
-
40°C…+60°C
-
40°C…+60°C
-
40°C…+60°C
-
40°C…+60°C
Pistol grip handle
Yes
Yes
Yes
Yes
Rotating neck
No
No
No
No
Changeable neck
No
No
No
No
© Kemppi