background image

Ordering codes

35

Packages

FA PRESSURE FLOW PACK includes:
FA Pressure flow control set (W007496) and FA Pressure flow hose 
(W007501)

W007515

FA PRESSURE FLOW SPIRAL HOSE 

10 m

W007506

FA PRESSURE CONDITIONER UNIT

W007504

FreshAir Pressure Flow Control set

valve and belt

W007496

Spare parts and consumables
FreshAir Pressure Noise silencer

W007498

FreshAir Pressure Control valve cap

W007499

FreshAir Pressure Air fitting

W007500

FreshAir Pressure Flow hose

flexible connection

W007501

FreshAir Pressure Flow Control belt

W007502

FreshAir Pressure Flow indicator

RD40x1/7“

W007503

FreshAir Pressure Conditioner unit

W007504

FreshAir Pressure Conditioner filter

W007505

FreshAir Pressure Flow Spiral hose

10 m

W007506

Содержание Beta 90 FreshAir

Страница 1: ...Product Training Material Version 1 0 Beta 90 FreshAir Delta 90 FreshAir welding respirators Protecting welders from the inside out...

Страница 2: ...2 Designed to provide necessary protection against associated health and safety risks and to ensure everyday user comfort Kemppi range of welder s respirators...

Страница 3: ...n Positive pressure systems are less fatiguing to use compared to negative pressure respirators Battery powered filter packs allow best mobility and improve independence of welder movement Reduce impo...

Страница 4: ...low Pack Beta 90 FreshAir with Flow Control pack P1700 Beta 90 FreshAir 9873065 FreshAir Flow Control pack W007513 Delta 90 FreshAir with Flow Control pack P1701 Delta 90 FreshAir 9873066 FreshAir Flo...

Страница 5: ...rove work Productivity and Motivation Lightweight and comfortable Choose Light weight 900g battery powered filter pack Choose Air line supply Air flow reduces welding lens misting Mechanical filter ef...

Страница 6: ...otection Provides safe clean and cool breathing air Excellent internal air distribution Positive pressure design makes breathing effortless Improve work Productivity and Motivation FreshAir prevents w...

Страница 7: ...battery powered units Higher initial purchase price and maintenance cost Time used limited by battery s charge life cycle to powered fan unit Cannot be used in Oxygen deficient environments 17 PAPR Po...

Страница 8: ...costs Comfortable and Light weight Limitations for airline supported systems Unexpected air loss eliminates all user protection Air delivery to mask or hood through a hose can be awkward to maneuvers...

Страница 9: ...and low weight 900g FreshAir Flow control with Alarm Battery powered Filter pack Blower unit Comfort belt Connection Hose Mains battery charger FreshAir Flow control with alarm incorporates an intelli...

Страница 10: ...use 0 C to 40 C Dimensions diameter height 132 55 mm Filter weight 100 g Certification EN 12941 type PSL R Optional pre filter prolongs main filter life Preventing premature clogging by larger particl...

Страница 11: ...hAir Pressure conditioner removes particles and unpleasant odor s from airline supply systems 11 FreshAir Pressure Flow control system FreshAir Pressure Flow control systems provide an ideal solution...

Страница 12: ...fumes include elements which are dangerous to health If unprotected tiny fume particles can pass deep into lung structure s This can cause variety of health issues Hazardous materials Enter to body in...

Страница 13: ...es oil mist vapors from solvents and various gases Some particular chemicals have damaging effects on lungs Others absorbed into bloodstream and damage various organs Target organs in human body Centr...

Страница 14: ...upon Physical biological and chemical properties of contaminants particle size and form Concentration in ambient air and time of exposure Volume of inhaled air More rapid respiration more inhaled airb...

Страница 15: ...ickel lesser amounts of iron Nickel alloys have much more Nickel in fume and very little iron How coatings change composition of welding fumes Vapours or fumes can come from coatings and residues of w...

Страница 16: ...ness sore throat eye irritation metal fever Bronchitis reprotoxic Chromium Ss Carcinogenic Nickel Ss Metal fever Carcinogenic Aluminium Irritation of respiratory organs metal fever Manganese Pneumonia...

Страница 17: ...17 Package choices including accessories FreshAir Flow Control Powered FreshAir Flow Control unit is supplied with PSL R filter Beta 90 FreshAir Delta 90 FreshAir...

Страница 18: ...Check whole respiratory systems air supply from blower to hood Fully charge battery before first use Air flow test Disconnect air hose from hood Cover disconnected end of air hose with hand Blower sta...

Страница 19: ...sor automatically regulates motor speed Compensate filter clogging and battery state If microprocessor cannot maintain adjusted airflow Acoustic signal alarms and LED diodes display RED color If possi...

Страница 20: ...attery capacity is Press and hold right button for more than 1 second More yellow LED diodes come on More clogged filter is After releasing buttons LED diodes return to green Light state is indicating...

Страница 21: ...ully dry before assembly and use About filters Filter units have high efficiency particle filter of class PSL R Filter must be checked regularly and replaced when necessary Make sure that new filter i...

Страница 22: ...ter Remove filter Hold gently rotate and pull filter away from main body Remove any dust with soft cloth Insert new filter In use with pre filter or odor filter place and fix it around new filter as t...

Страница 23: ...tch is positioned in middle of the battery Push units battery off by using thumbs Mount new battery Hold blower unit in same position as before Put battery to guide rail and push it back onto unit Lat...

Страница 24: ...y if the blower unit works with another charged battery Charge the battery If problem persists replace the battery Faulty motor circuit board or connector Contact your supplier Low airflow Blocked air...

Страница 25: ...shAir Flow Control Airflow 140 210 l min at 8 adjustable flow rates Weight of the blower unit incl the filter and battery 900 g Noise level 55 61 dB NiMh battery lifetime 500 700 charging cycles Charg...

Страница 26: ...ontrol Flexi hose W007487 FA Flow Control Flow indicator W007488 FA Comfort belt W007489 FA Basic filter 2 pcs standard W007490 FA Flow Control Sealing ring for filter W007491 FA Flow Control pre filt...

Страница 27: ...27 FreshAir Pressure Flow Control FreshAir Pressure Conditioner Beta 90 FreshAir Delta 90 FreshAir...

Страница 28: ...arantee supplied breathing air Quality Supplied compressed air in breathing air distribution system must meet EN 12 021 Standard FreshAir Pressure unit 1 pc Belt for the unit 1 pc Air hose 1 pc Air fl...

Страница 29: ...ion system is in range 300 1000 kPa Attach unit onto belt and fit connecting air hose to it Using quick coupling Connect pressure hose from compressed air source to FA Pressure unit FA Pressure Condit...

Страница 30: ...air supply and adjust flow rate to 170 l min Air flow is sufficient if cones top is in green area Read flow meter manually Close air supply Conditioner has still some pressure in it It will last for...

Страница 31: ...Clean with damp cloth Each part must be wiped dry after cleaning FA Pressure Conditioner Once a week drain condensate from bottom of the unit Use drain cock located at the base of unit Disconnect unit...

Страница 32: ...ir NOTE Filter does not remove CO and CO Read instructions for use and replacement Replacing FA Pressure Conditioner filters Unscrew top part of filter pressure container 6 screws Remove contaminated...

Страница 33: ...condition Fault Probable cause Recommendation The unit does not work at all Compressed air supply failure Check the compressed air source Hose damage Check that connecting hoses are not damaged The u...

Страница 34: ...mended temperature range at work 10 60 C Recommended air humidity range at workplace 20 80 Rh Certification Class 2A FreshAir Pressure Conditioner Maximum air flow 500 l min Weight without filter 6300...

Страница 35: ...e and belt W007496 Spare parts and consumables FreshAir Pressure Noise silencer W007498 FreshAir Pressure Control valve cap W007499 FreshAir Pressure Air fitting W007500 FreshAir Pressure Flow hose fl...

Страница 36: ...for high level personal protection Kemppi auto darkening welding filter 9873058 option can be fitted to either Beta 90 FreshAir and Delta 90 FreshAir Optical magnifying lenses can also be fitted for i...

Страница 37: ...ersions Allow exact start of welding Better visibility to weld joint Decrease need for spectacles use during welding Low welding current work Precise welding work Automatic Welding lense Improve weldi...

Страница 38: ...38 Replace lense Beta 90 FreshAir Delta 90 FreshAir...

Страница 39: ...shade number for different applications EN 169 EN 379 EN Shade number selection for arc welding filter EN Carbon arc gouging EN Plasma cutting Optional Kemppi auto darkening welding filter cover DIN 9...

Страница 40: ...Delta 90 Fresh Air welding filter lense standard 9873066 Spare parts and consumables Face seal x 1 W007516 Protection plate outside x 10 W007520 Welding filter lens DIN 8 90x110 x 1 9873241 DIN 9 90x...

Страница 41: ...ding filter 6800 g Inlet connection Compatible with RECTUS series 25 26 a CEYN320 Outlet connection Compatible with RECTUS series 25 26 a CEYN320 Recommended temperature range 10 60 C Recommended air...

Страница 42: ...066 FreshAir Pressure Flow Control pack W007515 Beta 90 FreshAir helmet 9873065 Protection plate x 1 9873253 Hatch spring x 2 4300700 Safety plate 90x110x1 5 x 1 9873254 Filter retaining spring x 1 31...

Страница 43: ...l Flexi hose W007487 FreshAir Flow Control Flow indicator W007488 Comfort belt W007489 Basic filter 2 pcs standard W007490 Flow Control pre filter 10 pcs W007492 Basic odour pre filter 10 pcs W007494...

Страница 44: ...44 FreshAir units are delivered with Quick guide Quick guide includes Instructions for use Multilingual Units regulations adjustments Spare parts Consumables Options...

Страница 45: ...45 Adjustment features Helmets can be equipped with Kemppi 1 1 1 1 rated Auto darkening welding filter Use all adjustment features for maximum protection and comfort...

Страница 46: ...46 Taking into use...

Страница 47: ...47 Taking into use...

Страница 48: ...48 Taking into use...

Отзывы: