![Kemppi Adaptive 170 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/kemppi/adaptive-170/adaptive-170_operating-manual_663245017.webp)
EN
5.
TROUBLESHOOTING
Problem
Cause
The wire does not move
or wire feed entangles
Feed rolls, wire conduit or contact tips are defective
• Check that feed rolls are not too tight or too loose
• Check that the feed roll groove is not too worn
• Check that the wire conduit is not blocked
• Check that there are no spatters on the conduit tip and that the hole is not
cramped or worn loose
Main switch indicator
light does not switch on
The machine has no supply voltage
• Check supply voltage fuses
• Check supply voltage cable and plug
Machine welds badly
Welding outcome is influenced by several factors
• Check wire feed is stable
• Check the trimming settings of welding power control and arc length
• Check that the earthing clamp is fixed properly, fixing point is clean, and
both cable and its connections are undamaged
• Check the flow of shielding gas from the tip of the welding gun
• Supply voltage is uneven, too low or too high
Over-heating indicator light
switches on
The machine has over-heated
• Check that cooling air can flow without obstructions
• Machine’s volume-capacity ratio has been exceeded; wait for the indicator
light to switch off
• The supply voltage is too low or too high
If the machine’s malfunction can not be corrected with these measures,
contact the Kemppi maintenance service.
15
M
inar
cM
ig 170 / © Kemppi O
y / 1117
Содержание Adaptive 170
Страница 2: ......
Страница 3: ...EN OPERATING MANUAL English MinarcMig 170 Kemppi Oy 1117...