EN
2.
INSTALLATION
2.1 Before use
The product is packed in cartons designed specifically for them. However, always make sure
before use that the products have not been damaged during transportation.
Check also that you have received the components you ordered and the instruction manuals
needed. Product packaging material is recyclable.
NOTE!
When moving the welding machine, always lift it from the handle, never pull it from the
welding gun or other cables.
Operating environment
This machine is suitable for both indoor and outdoor use. Always make sure that the air flow in
the machine is unrestricted. The recommended operating temperature range is -20…+40 °C.
Please read also the safety instructions concerning the operating environment earlier in this
manual.
2.2 Power source connection
The HF wire feeder is recommended to be used with the Kemppi HiArc power source, but it
can be used with other power source brands as well.
To connect the wire feeder to the power source, do the following:
1.
Attach the wire feeder interconnection cable to the plus connector of the power source.
2.
Attach the wire feeder control cable to the control connector of the power source.
NOTE!
Normally the wire feeder should be connected to the plus pole. However, with some filler
wires and shielding gases, you should connect the feeder to the minus pole, and the earth return
cable to the plus pole.
2.3 Shielding gas connection
The shielding gas hose is fixed to the magnet valve of the HF wire feeder.
Connect the other end of the gas hose to a gas cylinder’s control valve or to the shielding gas
distribution network at your worksite.
The thickness of the parent material, joint type and welding power define the required
shielding gas flow rate.
NOTE!
Make sure that you are using the correct type of shielding gas for the welding application.
To connect the shielding gas hose to a suitable regulator for MIG/MAG welding
1.
Connect the shielding gas hose to the gas cylinder’s control valve and tighten the
connector (connector is not supplied in the package).
2.
Adjust the shielding gas flow rate with the control valve screw.
3.
Always close the cylinder valve after use.
HF 10E, 10P
4