background image

KEMPPI OY

Hennalankatu 39

PL 13

FIN-15801 LAHTI

FINLAND

Tel +358 3 899 11

T358 3 899 428

[email protected]

www.kemppi.com

Kotimaan myynti:

Tel +358 3 899 11

T358 3 734 8398

[email protected]

KEMPPI SVERIGE AB

Box 717

S-194 27 UPPLANDS VÄSBY

SVERIGE

Tel +46 8 590 783 00

T46 8 590 823 94

[email protected]

KEMPPI NORGE A/S

Postboks 2151, Postterminalen

N-3103 TØNSBERG

NORGE

Tel +47 33 346000

T47 33 346010

[email protected]

KEMPPI DANMARK A/S

Literbuen 11

DK-2740 SKOVLUNDE

DANMARK

Tel +45 4494 1677

T45 4494 1536

[email protected]

KEMPPI BENELUX B.V.

Postbus 5603

NL-4801 EA BREDA

NEDERLAND

Tel +31 765717750

T31 765716345

[email protected]

KEMPPI (UK) Ltd

Martti Kemppi Building

Fraser Road

Priory Business Park

BEDFORD, MK44 3WH

UNITED KINGDOM

Tel +44 (0)845 6444201

T44 (0)845 6444202

[email protected]

KEMPPI FRANCE S.A.S.

65 Avenue de la Couronne des Prés

78681 EPONE CEDEX

FRANCE

Tel +33 1 30 90 04 40

T33 1 30 90 04 45

[email protected]

KEMPPI GmbH

Otto-Hahn-Straße 14

D-35510 BUTZBACH

DEUTSCHLAND

Tel +49 6033 88 020

T49 6033 72 528

[email protected]

KEMPPI SPÓŁKA Z O.O.

Ul. Borzymowska 32

03-565 WARSZAWA

POLAND

Tel +48 22 7816162

T48 22 7816505

[email protected]

KEMPPI AUSTRALIA PTY LTD.

13 Cullen Place

P.O. Box 5256, Greystanes NSW 2145

SMITHFIELD NSW 2164 

AUSTRALIA

Tel. +61 2 9605 9500

T61 2 9605 5999

[email protected]

OOO KEMPPI

Polkovaya str. 1, Building 6

127018 MOSCOW

RUSSIA

Tel +7 495 739 4304

T7 495 739 4305

[email protected]

ООО КЕМППИ

ул. Полковая 1, строение 6

127018 Москва

Tel +7 495 739 4304

T7 495 739 4305

[email protected]

KEMPPI, TRADING (BEIJING) COMPANY, 

LIMITED

Room 420, 3 Zone, Building B,

No.12 Hongda North Street,

Beijing Economic Development Zone,

100176 Beijing

CHINA

Tel +86-10-6787 6064

+86-10-6787 1282

T86-10-6787 5259

[email protected]

肯倍贸易(北京)有限公司

中国北京经济技术开发区宏达

北路

12

创新大厦

B

座三区

420

室 

(

100176

)

电话:

 +86-10-6787 6064

+86-10-6787 1282

传真:

 +86-10-6787 5259

[email protected]

KEMPPI INDIA PVT LTD

LAKSHMI TOWERS

New No. 2/770, 

First Main Road, 

KAZURA Gardens, 

Neelangarai, 

CHENNAI - 600 041 

TAMIL NADU

Tel +91-44-4567 1200

T91-44-4567 1234

[email protected]

www.kemppi.com

1910070

1117

Содержание 220

Страница 1: ...ng Svenska Bruksanvisning Norsk Brugsanvisning Dansk Gebrauchsanweisung Deutsch Gebruiksaanwijzing Nederlands Manuel d utilisation Français Manual de instrucciones Español Instrukcja obsługi Polski Инструкции по эксплуатации По русски EN FI SV NO DA DE NL FR ES PL RU ...

Страница 2: ......

Страница 3: ...EN OPERATING MANUAL English Minarc 220 Kemppi Oy 1117 ...

Страница 4: ... 2 4 Cable connections 6 2 5 Welding power selection and electrodes 6 2 6 Function controls and indicator lights 8 2 6 1 Welding current regulation and remote control 9 2 6 2 MMA welding settings 9 2 6 3 TIG welding function 9 2 6 4 The VRD feature 9 3 MAINTENANCE 10 3 1 Daily maintenance 10 3 2 Disposal 10 4 ORDERING NUMBERS 11 5 TROUBLESHOOTING 12 6 TECHNICAL DATA 12 2 Minarc 220 Kemppi Oy 1117 ...

Страница 5: ...hese sections carefully and follow their instructions 1 2 MACHINE PROPERTIES The Minarc 220 is intended for use in a three phase electric network It is designed to be a compact and efficient direct current MMA TIG machine Extremely light in weight for its high 220 A output power the machine is easy to carry to the work place with either the inbuilt moulded carry handle or the shoulder strap provid...

Страница 6: ... molten pool into which filler wire of a similar alloy composition is slowly melted The molten weld pool and filler wire are protected from the harmful effects of atmospheric contamination by an inert shielding gas that flows out from the TIG welding torch s ceramic nozzle at a rate of approximately 8 15 litres per minute Gas regulator flow meter and pure argon shielding gas are not provided in th...

Страница 7: ...g spatter Make sure the airflow to and from the machine is unrestricted 2 2 GENERAL VIEW OF THE MACHINE 1 2 3 4 1 MMA welding cable 2 Earthing cable and earthing clamp 3 Main switch 4 Mains cable 2 3 DISTRIBUTION NETWORK All regular electrical devices without special circuits generate harmonic currents into distribution network High rates of harmonic current may cause losses and disturbance to som...

Страница 8: ... machine The maximum length for the extension cable is 50 m Restrictions on generator type and power may apply in generator use Fault free operation of the machine requires a sufficiently high power generator The power recommendation is more than 15 kVA Earthing cable Connect the earthing cable to the negative pole in MMA welding and to the positive pole in TIG welding Before you start welding cle...

Страница 9: ...A 50 80 A 80 110 A 110 150 A 140 200 A 200 220 A TIG welding electrodes and gas nozzles In DC TIG welding we recommend the use of the WC20 grey type electrode however other types are available The welding electrode size diameter is selected depending on the welding current power to be used An electrode with an insufficient diameter compared to the welding current will melt while excessive electrod...

Страница 10: ...g value table Switching the machine on When you power on the machine the green standby indicator and the main switch are lit If the machine overheats or the supply voltage is too high or too low the welding operation automatically switches off and the yellow overheating indicator is illuminated The light switches off again when the machine is ready for operation Make sure that there is enough spac...

Страница 11: ...ss selection button 3 Ignition with switch control TTC 220 GV torch When using the TTC 220 GV torch the TIG arc can be ignited with switch control Gently touch the work piece with the electrode then press the torch switch while quickly lifting the electrode off the work piece This will ignite the arc quickly and efficiently To stop welding release the switch which will stop the current and turn of...

Страница 12: ...pen the electrode or replace a damaged one Check the tightness of the earthing cable connections Check the condition of mains and welding cables and replace damaged cables 3 2 DISPOSAL Do not dispose of electrical equipment with normal waste In observance of European Directive 2002 96 EC on waste electrical and electronic equipment and its implementation in accordance with national law electrical ...

Страница 13: ...0 m 6184202 Earthing cable 16 mm 5 m 6184113 Earthing cable 25 mm 5 m 6184211 Earthing cable 25 mm 10 m 6184212 TIG torches TTC 220GV Switch control and RTC10 remote 627022304 TTM 15 BC Scratch start 627143201 Remote control units R 10 5 m 6185409 R 10 10 m 618540901 RTC10 6185477 Other accessories Gas flow gauge AR clock 6265136 Carrying straps 9592162 Supply voltage cable W002982 11 Minarc 220 K...

Страница 14: ...heating indicator lit The device has overheated Ensure that cooling air has unrestricted flow If the machine s duty cycle has been exceeded wait for indicator to turn off Too low or high supply voltage If the machine s malfunction is not eliminated with these measures contact KEMPPI service 6 TECHNICAL DATA Minarc 220 Connection voltage 3 50 60 Hz 400V 20 15 Rated power at max current MMA 8 2 kVA ...

Страница 15: ...G 0 92 MMA 0 91 Efficiency at 100 ED TIG 0 80 MMA 0 86 Stick electrodes MMA ø 1 5 5 0 mm External dimensions L W H 400 180 340 Weight 9 2 kg 10 2 kg with connector cable Temperature class H B Degree of protection IP23S EMC class A Minimun short circuit power Ssc of supply network 1 6 MVA Operating temperature range 20 C 40 C Storage temperature range 40 C 60 C Recommended generator 15 kVA See para...

Страница 16: ...PPI GmbH Otto Hahn Straße 14 D 35510 BUTZBACH DEUTSCHLAND Tel 49 6033 88 020 Telefax 49 6033 72 528 sales de kemppi com KEMPPI SPÓŁKA Z O O Ul Borzymowska 32 03 565WARSZAWA POLAND Tel 48 22 7816162 Telefax 48 22 7816505 info pl kemppi com KEMPPI AUSTRALIA PTY LTD 13 Cullen Place P O Box 5256 Greystanes NSW 2145 SMITHFIELD NSW 2164 AUSTRALIA Tel 61 2 9605 9500 Telefax 61 2 9605 5999 info au kemppi ...

Отзывы: