45/49
PROBLEMS CHECK LIST
PROBLEM
PROBABLE CAUSE
SOLUTION
Pilot will not light
Gas valve may be OFF
Tank fuel empty
Opening blocked
Air in supply system
Loose connection
Low gas pressure
Turn the gas valve ON
Refill LPG tank
Clean or replace opening
Purge air from lines by pressing the
control knob until you smell gas
Check all fittings
Replace cylinder with a new cylinder
Pilot will not stay on
Debris around pilot
Loose connection
Thermocouple bad
Gas leak in line
Lack of fuel pressure
Clean dirty area
Tighten connections
Replace thermocouple
Check connections
Tank near empty. Refill or replace LPG
tank
Burner will not light
Pressure is low
f
Opening blocked
Control not ON
Thermocouple bad
Pilot light assembly bent
Not in correct location
Tank near empty. Refill or replace LPG
tank
Remove and clean
Turn valve to ON
Replace thermocouple
Place pilot properly
Position properly and retry
Burner flame is low
Supply hose is bent or twisted
Straighten hose and perform leak test
on hose
Emitter glows uneven
Low gas pressure
Base is not on a level surface
Replace cylinder with a new cylinder
Place heater on a level surface
Thick black smoke
Blockage in burner
Turn off the heater and let it cool.
Remove blockage and clear burner
inside and outside
Carbon build-up
Dirt or film on reflector and flame screen
Clean reflector and flame screen
EN