50
12mm
Air gap
150
Run a bead of silicone down
the vertical seam of the outer
casing to the flashing
Ceiling trim
7” Flue
TEMPO 3 VER 2 FREESTANDING
FLAT CEILING INSTALLATION
4.5” Flue
Flash roof to outer casing
(supplied by installer)
INSTALLATION INSTRUCTION
Pop rivet or
screw brackets to
the outside of the
outer casing
Short tube fits into flue
pipe. All flues should
be trimmed level
DETAIL A
DETAIL B
7” Decro
A
Stainless steel flue pipe.
All flue pipes must be
connected with pop rivets
supplied by installer
All casing flue pipes must
be connected with pop
rivets supplied by installer
Flue system to be installed
to suit AS/NZS 2918.2001
50
Vented cap
B
Support outer flue with
Brackets supplied
Bracing supplied by installer
NOTE:- When Decromesh/Heatshield is fitted, it must
finish a minimum of 600mm below the ceiling or extend
through the ceiling drop box into the outer flue casing
9” Flue
All
4.5” assembled flues must
have the crimps pointing
downwards
crimped
plain
DETAIL C
DETAIL D
All
7”-9” assembled flues must
have the crimps pointing upwards
plain
crimped
C
D
NOTE:- When Decromesh/Heatshield is fitted, it must
finish a minimum of 600mm below the ceiling or extend
through the ceiling drop box into the outer flue casing
21/08/2020
Ver.7
8