OPERATING HINTS

To get the best from your Kemlan heater it is essential that you use good firewood, and use it correctly Many people do not understand the 
principle of using a wood burning appliance and we suggest that it will be worth your while to study the following extract from a well known 
American publication.

PRINCIPLES OF COMBUSTION: HOW WOOD BURNS

Technically, wood does not burn.  What burns is the volatiles and charcoal that are created.  That is why wood will not catch on fire 
immediately when you put a match to it; it has to first undergo the chemical changes that create the volatiles, and a match does not create 
enough heat to activate the process. As kindling and paper evaporate the moisture in the wood, the wood absorbs heat. At a certain point, 
gases are given off and when these volatiles reach 480 degrees F, or the “Flash point”, as it is called, they will burst into flame if sufficient 
oxygen is present. The volatiles give off more heat than does charcoal, which is why a fire with flames (which burn the volatiles) produces 
more heat than one that is all charcoal.

Since the volatiles are gases and since heat rises, taking the gases with it, it is very easy to create a situation in which most of the volatiles go 
up the chimney almost as soon as they are produced. This is what happens with a roaring fire and, to a lesser extent, with an open fire. One of 
the reasons (but only one) that a freestanding wood stove produces more heat than an open fire is that the volatiles are contained within the 
firebox and are not so quickly dissipated up the chimney. A stove that is baffled is merely one that has interior construction design to keep the 
volatiles in the firebox longer; the longer they are in the firebox, the more completely they burn.  The more completely they burn, the more heat 
is produced.  It’s that simple.

Since the flames burn the volatiles and produce heat, the ideal situation is the longest possible flame path. As soon as wood burners 
understand this, they tried to devise ways of making the flame path longer than in an ordinary open fire. Even though the role of oxygen in 
combustion was not under-

stood in Ben Franklin’s time, Franklin did realize the importance of more completely burned volatiles. His solution 

was to try to invent a downdraft stove
– one that sent the volatiles back down through the fire – but he never succeeded in getting it to work. A downdraft goes against the nature of 
volatiles, which is to rise. In more recent times, there have been some successful downdraft 

– or partial downdraft – stoves created and some 

of the fireplace stoves and units utilise this principle. Ideally, it would be best if the volatiles could be redirected down through the fire several 
times, until they were al- most totally consumed. This would not only make the maximum use of the heat potential of the wood; it would reduce 
creosote build-up to almost zero. Perhaps someday an ingenious inventor will design a unit that does this; so far no has been able to.

MOISTURE AND COMBUSTION

As we have seen, dry wood ignites faster and burns better 

– with higher heat production – than wet or green wood. The difference between 

the amount of heat produced by dry wood and green wood is so great that a dry softwood of good grade will produce more heat than green 
hardwood. Green white ash, for instance, is not as good a fuel as dry tamarack.

The reason for the superiority of dry wood is easy to understand. Heat cannot be produced until moisture has been driven off. Since even so-
called seasoned dry wood contains approximately 20 percent moisture, it takes time for any fire to begin producing useable heat. Wet wood, 
which can have a moisture content of over 100 percent (due to the way moisture is measured), will take that much longer to produce heat. 
Meanwhile, the fire will produce smoke and creosote and very little heat.  This was brought sharply to my attention when I installed my first 
wood heater.  To my surprise and delight, I found it comfortably heated eight rooms, where I had expected to heat only two or three. After 
some time, when I had someone helping me run the fire, I suddenly noticed that the house was chilly. We added more wood and adjusted the 
draft controls, but nothing we did seemed to help. It finally occurred to me to check the woodpile. My friend had been getting green wood from 
a stack that was drying, instead of from the dry-wood stack. The difference the green wood made was so dramatic I will never forget it.

HOW TO TEST WOOD FOR DRYNESS

There are two easy ways for even a novice to spot dry wood. Dry wood tends to “check”. Look at the log ends and you will see cracks radiating 
from the centre of the log.  If the logs have been split, the cracks will be harder to find because wood tends to split along the cracks. 

Another test for dry wood is the sound it makes when two logs are banged against each other. Green wood will make sort of a dull thud; dry 
wood makes a nice crisp, sharp sound.  Once you have heard the two, you will remember the difference.

FROM THE ABOVE EXTRACT SEVERAL FACTS BECOME APPARENT:

1. It is vital that your firewood be dry and seasoned. 

2. A good hot fire of kindling and smaller pieces of fuel must be established before adding larger logs.

3. The larger logs should be well alight before slowing down the combustion by adjusting the air intake.

4. A hot bed of coals needs to be maintained to ensure continued combustion in the firebox.

5. When new timber is added to the firebox the air control should be opened until the fuel is well alight before damping it down again. This will  
take from 10 to 20 minutes.

6. When setting the controls for overnight burn you will need to experiment with the settings to suit your particular type of fuel. Very dense 
hardwood requires more air to combust and over damping will result in charring and smoking causing the glass in the door to become dirty. 
The same will apply with fuel which is not fully seasoned or is not dry enough. Kemlan have followed a policy since 1969 of checking on all 
complaints about poor performance of their heaters and apart from a few instances of incorrect installation (mostly insufficient flue length) all 
problems have been directly related to incorrect operation and/or poor fuel. We know you will experience many years of satisfaction from your 
heater if you follow the above advice.

ver.5

20/08/2020

19

Содержание CELESTIAL 900 WITH FAN

Страница 1: ...ETION 10 YEAR FIREBOX WARRANTY The firebox is covered by a 10 year warranty Other parts are covered by a one year limited warranty Head Office 13 French Avenue Brendale Queensland 4500 Telephone PH 07 3490 5500 Facsimile FAX 07 3490 5520 Website www jetmaster com au Business hours Monday to Thursday 7 30am 4 00pm Friday 7 30am 2 00pm Email sales jetmaster com au 20 08 2020 ver 5 1 ...

Страница 2: ...WITH FAN AND HEAT DUCTING BOX FOR MASONRY HEBEL B H I D H DIMENSIONS DESC MODEL A B C D E F G H I J K L M CELESTIAL 900 WALL INSERT 468 495 608 1054 252 610 202 528 1180 672 776 268 L M ver 5 J K FASCIA 960 442 20 08 2020 2 ...

Страница 3: ...T B A A UNIT HEIGHT ABOVE FLOOR 200 300 400 500 600 700 B HEARTH DIMENSION FORWARD OF UNIT 725 715 665 594 492 335 ver 5 UNDERNEATH UNIT AND HEARTH THICKNESS MUST BE A MINIMUM 18mm NON COMBUSTIBLE MATERIAL FC SHEET OR SIMILAR 20 08 2020 3 ...

Страница 4: ... UNIT X Y NOTE IF Y IS LESS THAN 200mm THEN REFER TO HEARTH MEASUREMENT ON PREVIOUS PAGE X MIN DEPTH MEASUREMENT mm 300 Y MIN HEIGHT INCREASE mm 200 ver 5 UNDERNEATH UNIT AND HEARTH THICKNESS MUST BE A MINIMUM 18mm NON COMBUSTIBLE MATERIAL FC SHEET OR SIMILAR 20 08 2020 4 ...

Страница 5: ...CK 222 4 BAFFLE PLATE SIDE OF 222 MM SHOULD EXTEND FROM SIDE TO SIDE 6 SLIDE THE BAFFLE PLATES ATOP THE OTHER 2 BAFFLE PLATES INTO THE MIDDLE POSITION AS SHOWN LEAVE GAP OF 1 2 MM IN BETWEEN PLATES THE GAPS SHOULD BE ROUGHLY IN THE MIDDLE OF THE AIR TUBES UNIT IS NOW READY FOR USE 5 RE PLACE MIDDLE AIR TUBE BACK INTO POSITION NB MAKE SURE OPEN END OF AIR TUBE IS PLACED INTO REAR OPENING CLOSED END...

Страница 6: ...inless steel flue pipe All flue pipes must be connected with pop rivets supplied by installer Rear of unit to Hebel Block 25mm min Hebel Block min thickness 75mm 25mm min clearance between 10 flue and framing 6 Flue Inlet air vents into chase Outlet air vents from chase DETAIL A All 8 10 assembled flues must have the crimps pointing upwards crimped plain All 6 assembled flues must have the crimps ...

Страница 7: ...0mm min Below ceiling Triple skin flue system 10 8 and 6 Flue system to be installed to suit AS NZS 2918 2001 25mm min clearance between 10 flue and ceiling framing Inlet air vent 240 x 90 6 Flue Outlet air vent 240 x 90 Located on the front or side of the chase 55mm air gap 9mm Fibre cement sheet Register plate with vented 8 and 10 upstands 600mm min below ceiling CELESTIAL 900 MASONRY BLOCK CONS...

Страница 8: ...ver 5 1165 650 NOTE THE APPLIANCE WILL NEED 505mm DEEP OPENING TO THE BACK OF CHASE CELESTIAL 900 MASONRY OPENING CUT SIZE 20 08 2020 8 ...

Страница 9: ... ONLY NEEDS TO BE NON COMBUSTIBLE TO CEILING NOTE SIDES AND BACK CAN BE COMBUSTIBLE 9mm FIBRE CEMENT 13mm FYRECHECK OR SIMILAR PRODUCT FRONT FACE NEEDS TO BE ALL NON COMBUSTIBLE MATERIAL STEEL TRACK 25mm PYROTEK BOARD ASSEMBLY TOP VIEW FRONT VIEW TIMBER FRAME 15mm CLEARANCE FROM ZERO CLEARANCE BOX COMBUSTIBLE MATERIAL 25mm CLEARANCE FROM OUTER FLUE TO COMBUSTIBLE MATERIAL 20 08 2020 9 ...

Страница 10: ...ver 5 A B J H I C D E F G L K A B C D E F G H I J K L CELESTIAL 900 WITH FAN 933 1254 523 626 626 1073 215 623 95 295 228 304 DIMENSIONS FOR WHITE BOARD ZERO CLEARANCE BOX 20 08 2020 10 ...

Страница 11: ...FASCIA TO SLIDE BETWEEN THE BOX AND THE WASHER 3 BEND THE SILICONE TABS INTO POSITION THIS TAB SHOULD BE PARALLEL TO THE FRONT OF THE FASCIA WHEN IN THE CORRECT POSITION 4 SLIDE FASCIA INTO THE REQUIRED POSITION THEN HAND TIGHTEN THE SCREWS AS REQUIRED OR USE AN APPROPRIATE ALLEN KEY OR PLIERS USE A TOUCH UP PAINT ON THE SCREW HEADS AS REQUIRED 5 RE INSTALL THE DOOR BACK ON USE THE REVERSE METHOD ...

Страница 12: ... THAT THE DOOR WILL LOCK PROPERLY 3 LOOSEN THE 2 BOLTS AS REQUIRED DO NOT UNSCREW THE BOLTS ALL THE WAY OUT 4 PUSH THE PACKER FROM THE BOTTOM EDGE OF THE ADJUSTMENT ANGLE UNTIL FULLY REMOVED ONLY TAKE OUT WHAT IS NECESSARY RE POSITION THE ADJUSTMENT ANGLE AT THE MARKERS AND TIGHTEN NOTE UP TO 4 PACKERS CAN BE REMOVED IF NECESSARY 5 CLOSE THE DOOR AND CHECK IF THE LATCH LOCKS PROPERLY THE ADJUSTMEN...

Страница 13: ...T AND TILT UP THE FRONT EDGE OF THE FAN CASSETTE AT THE LAST MOMENT TO RELEASE IT FROM THE APPLIANCE CAVITY 5 PULL FAN CASSETTE AWAY FROM THE APPLIANCE TAKE NOTE OF THE FAN POSITION WHILST STILL IN THE CASSETTE THIS WILL BE IMPORTANT DURING RE INSTALLATION EARTH WIRE CONNECTORS TO FASCIA CONNECTORS TO FAN WIRES 6 USE A FLAT SURFACE AND LAY THE FAN CASSETTE UPSIDE DOWN REMOVE THE 2 SCREWS HOLDING T...

Страница 14: ... COMPLY WITH AS NZS 2918 INCREASE FROM 1000 MIN UNTIL CLEAR WITHIN 3000 OF TOP OF FLUE 3000 ANY NEARBY STRUCTURE 3000 MORE THAN 3000 600 MIN 3000 1000 MIN IF CLEAR WITHIN 3000 OF TOP OF FLUE INCREASE AS NECESSARY UNTIL NOTHING WITHIN 3000 OF FLUE TOP 600 MIN 3000 OR LESS ver 5 20 08 2020 15 ...

Страница 15: ...ver 5 20 08 2020 16 ...

Страница 16: ...mately 10 to 15 minutes until the new pieces are burning well then it may be returned to its desired setting 6 To set the fire for overnight burn two thirds fill the firebox with hardwood and fully open the air inlet Once the fire is burning well the air inlet control should be shut down approximately three quarters of its travel Setting the air inlet control may be varied to suit your particular ...

Страница 17: ...ver 5 20 08 2020 18 ...

Страница 18: ... with higher heat production than wet or green wood The difference between the amount of heat produced by dry wood and green wood is so great that a dry softwood of good grade will produce more heat than green hardwood Green white ash for instance is not as good a fuel as dry tamarack The reason for the superiority of dry wood is easy to understand Heat cannot be produced until moisture has been d...

Страница 19: ... for damaged heater 5 CLAIMS 5 1 I Kemlan will provide a full replacement of the heater in the first five years after installation ii Replacement in the subsequent five years i e sixth to tenth year after installation will be on the following basis Owner will pay fifty percent of the current retail price if the claim is made in the sixth year tenth year after purchase 5 2 Replacement of heater sub...

Страница 20: ...ver 5 NOTES 20 08 2020 21 ...

Страница 21: ...ver 5 20 08 2020 22 ...

Страница 22: ...ver 5 20 08 2020 23 ...

Отзывы: